Carrier 19EX, 17 NOZZLE-IN-HEAD Waterboxes, Frame 3 and 5 Marine Waterboxes, Cooler Waterbox

Page 18

NOZZLE-IN-HEAD WATERBOXES

COOLER WATERBOX

Pass

In

Out

Arr.

Code

 

 

 

1

8

5

A

5

8

B

 

2

7

9

C

4

6

D

 

3

7

6

E

4

9

F

 

CONDENSER WATERBOX

Pass

In

Out

Arr.

Code

 

 

 

1

11

2

P

2

11

Q

 

2

10

12

R

1

3

S

 

3

10

3

T

1

12

U

 

 

 

 

 

NOTES:

1. Frame 5 condenser available in 1 and 2 pass only. Frame 3 in 2 and 3 pass only.

2. The vents for these waterboxes, located in the covers are 1 in. FPT at the top of each box, and the drains are 1 in. FPT, at the bottom.

3. Victaulic connections are standard.

4. Flanged waterbox connections are optional.

FRAME 3 AND 5 MARINE WATERBOXES

COOLER WATERBOX

Pass

In

Out

Arr.

Code

 

 

 

1

8

5

A

5

8

B

 

 

7

9

C

2

4

6

D

 

16

17

G

3

7

6

E

4

9

F

 

CONDENSER WATERBOX

Pass

In

Out

Arr.

Code

 

 

 

 

10

12

R

2

1

3

S

 

13

15

Y

3

10

3

T

1

12

U

 

 

 

 

 

NOTES:

1. Frame 3 condenser available in 2 and 3 pass only. Frame 5 condenser available in 2 pass only.

2. The vents for these waterboxes are 1 in. FPT at the top of each box, and the drains are 1 in. FPT, at the bottom.

3. Victaulic connections are standard.

4. Flanged waterbox connections are optional.

Fig. 13 Ð Nozzle Arrangements

18

Image 18
Contents Installation Instructions Contents Model Number Identication Typical 19EX Installation 19EXTypical 17EX Installation 17EX Front View 19EX Front ViewTypical Top View 19EX Shown Item no Torque Ft-lbHeat Condenser LENGTH² Width Height Tube PullComponent DIAMETER²² LENGTH²² Diameter Length Nozzle TypeDry Operating²² Refrigerant Water Condenser Total Weight Condenser ChargeRefrigerant Charge Dry Operating²² RefrigerantAuxiliary Connection Sizes Additional Cooler WeightsAdditional Condenser Weights CondenserCompressor Weights Total 19EX Motor Weights 60 HzTotal 19EX Motor Weights 50 Hz Total 17EX Drive Component WeightsÐ 17EX Motors Ð Total Weight, Lbs English Ð 17EX Motors Ð Total Weight, Kg SIMarine Waterbox Cover Weights NIH Waterbox Cover WeightsPsi KPa Cooler Sizes DimensionsCooler Sizes 31-33 Ft-in 31-33Machine Vibration Isolation Connect Piping Cooler Waterbox NOZZLE-IN-HEAD WaterboxesFrame 3 and 5 Marine Waterboxes Pass Out ArrFrame 4 Marine Waterboxes Pumpout UnitWater Piping, Oil Cooler to Chilled Water Circuit Typical Relief Valve Locations and Data ValvesIndividual Component Ratings PH-HZGeneral Page General Oil Pump Wiring 19EX Shown8772 02525Insulation Requirements 11¤8 Foam Tubing 15¤819EX Chillers Front View Plan ViewInstallation START-UP Request Checklist Testing YES/NO Date to be Completed