WM-70 PLASTER/MORTAR MIXER — START-UP PROCEDURE
This section is intended to assist the operator with the initial
DO NOT use your mixer until this section is thoroughly understood.
| WARNING | Explosive Fuel |
| Hazard | |
|
|
Failure to understand the operation of the
See Figure 5 for the location of any control referenced in this manual.
| CAUTION | Respiratory Hazard |
NEVER operate the mixer in a confined area or enclosed area structure that does not provide ample free flow of air.
Start-up Procedure(Gasonline Engine)
The following steps outline the procedure for starting the engine. Depending on the type of engine employed in the mixer the steps may vary slightly. If your mixer has an electric motor disregard this section.
1.Move the fuel
2.To start a cold engine, move the choke lever (Figure 12) to the CLOSED position.
Figure 12. Choke Lever
3.Move the throttle lever (Figure 13) away from the slow position, about 1/3 of the way toward the fast position.
Figure 13.Throttle Lever
Figure 11. Fuel Shut-OFF Lever