Instructions for the installer
5. Adapting to different types of gas
Before performing any cleaning or maintenance work, detach the hob from the electrical socket.
The hob has been inspected for G20 (2H) natural gas at a pressure of 20 mbar.
For functioning with other types of gas the nozzles must be replaced and the primary air adjusted.
To replace the nozzles and regulate the burners, you have to remove the top as described in the following paragraph.
5.1Removing the hob
Remove all of the burner components by following the numerical sequence shown in the figure:
•remove all of the knobs (1) by pulling them upward;
•remove the grids (2), lifting up one of the two horizontal spokes;
•remove the burner caps (3) and flame caps (4);
•with wrench A (supplied), open the bayonet clamps on the burner rings by levering on guides B;
•after having removed all of the
25 |