Instructions for the installer
5.3 Regulation for natural gas
The hob has been inspected for G25 (2L 3B/P) at a pressure of 2 mbar. To allow the unit to work with this type of gas, perform the same operations described in paragraph “5.2 Regulation for LPG”, but choose the nozzles and regulate the primary air for natural gas, as shown in the following table and in paragraph "5.4 Regulation of primary air”. After the regulations have been carried out, restore the seals with sealing wax or equivalent material.
|
| Rated |
|
|
|
|
|
|
Burner |
| heating |
| Natural gas – G25 25 mbar |
| |||
|
| capacity |
|
|
|
|
|
|
|
| (kW) |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| Nozzle diameter |
|
| Reduced flowrate |
|
|
|
|
| 1/100 mm |
|
| (W) |
|
|
|
|
|
|
|
| ||
Auxiliary (1) |
| 1.05 |
| 76 |
|
| 380 |
|
|
|
|
|
|
|
| ||
| 1.65 |
| 98 |
|
| 380 |
| |
|
|
|
|
|
| |||
Rapid (3) |
| 2.7 |
| 123 |
|
| 650 |
|
|
|
|
|
|
| |||
Rapid (4) |
| 3.1 |
| 130 |
|
| 750 |
|
|
|
|
|
|
| |||
Ultra rapid (5) |
| 3.9 |
| 150 |
|
| 1400 |
|
5.4Regulation of primary air
Referred to distance “X” in mm.
BURNER |
| G25 |
|
|
| 25 mbar |
|
|
|
|
|
|
|
|
|
Auxiliary (1) |
| 1.5 |
|
|
|
| |
| 1.0 |
| |
|
|
| |
Rapid (3) |
| 1.0 |
|
|
|
| |
Rapid (4) |
| 1.5 |
|
|
|
| |
Ultra rapid (5) |
| 1.5 |
|
G30/G31
28/37 mbar
2.0
1.5
5.0
10.0
4.0
31