Smeg CIR60XS manual Instructions for the installer

Page 7
be protected in accordance with Clause 5.12.1.2 to a height C of not

Instructions for the installer

be protected in accordance with Clause 5.12.1.2 to a height C of not

less than 150 mm above the hob for the full dimension (width or depth) of the cooking surface area. Where the cooking appliance is

fitted with a ‘splashback’, protection of the rear wall is not required.

3Additional requirements for Freestanding and Elevated Cooking

Appliaces – (Measurements D & E)

Where D, the distance from the periphery of the nearest burner to a horizontal combustible surface is less than 200 mm, then E shall be 10 mm or more, or the horizontal surface shall be above the trivet. See insets above.

NOTES

1Requirement 3 does not apply to a freestanding or elevated cooking appliance which is designed to prevent flames or the cooking vessels from extending beyond the periphery of the appliance.

2The ‘cooking surface area’ is defined as that part of the appliance where cooking normally takes place and does not include those parts of the appliance containing control knobs.

3For definition of hob, see Clause 1.4.64.

4For definition of trivet, see Clause 1.4.109.

5Consideration is to be given to window treatments when located near cooking appliances. See Clause 5.3.4.

9

Image 7
Contents Index NEVER UNPLUG BY PULLING ON THE CABLE Introduction1. INSTRUCTIONS FOR SAFE AND PROPER USE THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USETHE PLATE ON THE CASING MUST NOT BE REMOVED 2. POSITIONING OF HOB Instructions for the installer2.1.1 Attachment to support structure Instructions for the installer REQUIREMENTS 2.2 Clearance above and around domestic appliancesbe protected in accordance with Clause 5.12.1.2 to a height C of not 2.4 Discharge of combustion products 2.3 Room ventilation3. GAS CONNECTION 4. ELECTRICAL CONNECTION 5. GAS CONNECTION 5.2 Ventilation of rooms 5.1 Connection to LPG5.3 Discharge of combustion products 6.1 Removing the hob 6. ADAPTATION TO DIFFERENT TYPES OF GASBurner 6.2 Regulation for LPG7.2 Regulation of minimum for LPG 7. FINAL OPERATIONS6.3 Regulation for natural gas 7.1 Regulation of minimum for natural gasSemi-rapid This must be done by a qualified technicianBURNERS AuxiliaryInstructions for the user 8. USING THE HOBSemi-rapid BurnerØ min. and max. in cm Auxiliary8.4.2 Using the electric elements 9.1.1 Regular daily cleaning of the hob 9. CLEANING AND MAINTENANCE9.1 Cleaning 9.2 Cleaning of cooking hob components9.2.1 Ignition plugs and safety devices 9.3 Preventive maintenance9.2.2 The cover WHAT TO DO 10.PROBLEMS AND CAUSESPROBLEM CAUSEPage 914772609/ B