Andrew ATC200-Lite manual If satisfied with new configuration data, click ‘Yes’

Page 36

Section 5–Device Configuration

ATC200-Lite Teletilt® Remote Control Downtilt System

Alternately, the suggested date may be erased and a new date entered, or the field may be left blank. When a date is entered, it must be formatted as shown in Figure 5-2 (A ‘forward slash’ character placed between the month and day and a ‘forward slash’ character placed between the day and year). i.e., August 4, 2004 would be typed as 08/04/04.

The installer’s ID must be 1 to 5 characters in length with any combination of letters and numbers.

Values specified for the frequency band, sector, technology, location, and mechani- cal tilt are used for reference only and have no direct affect upon the actuator/ antenna that is being configured.

8.Carefully review all selections. If satisfied that all are correct, click ‘Configure’. Alternately, the user may go back and edit/change any of the selections made or click the ‘Cancel’ button to quit this process without making any changes to the actuator’s current configuration.

9.After the ‘Configure’ button has been activated, the user will be prompted to confirm the desire to make these changes to the actuator. Click ‘Yes’ to proceed with the changes, or click ‘No’ to return to the configuration screen (Figure 5-3).

When proceeding to make changes, the settings selected will be sent to the actuator. The main screen will change the status of this device to ‘Configuring’ to indicate that new set- tings are being sent to the actuator.

10.When the configuration process is complete, a pop-up dialog box will display the results. Normally, the dialog box will show that the changes were successfully sent to the device (Figure 5-4). However, if the configuration process was unable to communicate with the actuator for any reason, a failure message will appear.

If satisfied with new configuration data, click ‘Yes’.

Figure 5-3. Choosing to Continue with Configuration Changes to the Device.

Click ‘OK’.

Figure 5-4. Confirmation of Configuration Changes to Device.

5-

May 2005

Bulletin 639510

Image 36
Contents Andrew Corporation Base Station Antennas Telecom Parkway Richardson, Texas Tel 214 Fax 214Page Revision History Revision No Date Description of Changes None May ReleasedATC200-Lite Teletilt Remote Control Downtilt System Iii ESD Wrist Strap ATC200-Lite Teletilt Remote Control Downtilt System This page intentionally left blank Contents Part Numbering Scheme and Ordering Guide 10-1 Controller Setup ATC200-Lite Series Controller SetupSystem Description ATC200-Lite Series Controller CommunicationATC200-Lite Controller with RS-232 Serial Cable Attached Example of ATC200 System Diagram This page intentionally left blank Program Installation Program Download and InstallationSetup Introduction Screen Software Upgrades and Antenna Definition File Updates Completing Setup ScreenMay Bulletin Program Startup and Configuration Preparing for Program StartupSerial Port Selection at Program Startup ATC200-Lite Application IconSelecting a Serial Port Beginning Program Operation Antenna Definition File SelectionSelecting ‘Antenna Files’ from Main Menu This page intentionally left blank Device Discovery and Addressing Device SearchClick ‘OK’ Bulletin May Addressing Click ‘Remove Device’Confirmation of Device Removal 10. Assigning a New Address 13. Closing ‘Manual Addressing’ Screen This page intentionally left blank Device Configuration Selecting Device to be ConfiguredMake appropriate selections and text entries Bulletin May If satisfied with new configuration data, click ‘Yes’ Bulletin May This page intentionally left blank Selecting Device for Electrical Downtilt Adjustment Changing the Electrical Downtilt on a Single AntennaClick ‘Activate’ Enter a new electrical tilt angle Click ‘OK’ May Bulletin Changing the Electrical Downtilt on a Group of Antennas Selecting an Antenna Within a SectorAdding Devices to be Included in the Sector Move Entering New Electrical Tilt Setting for Sector Move Click ‘OK’ Saving a Site Report or Site Configurations Saving/Viewing a Site Report Formatted to Open in WordClick ‘Save’ Assign a filename to the report Select the ‘txtrpt’ file Go to ‘ATC200SiteFiles’ directory Report File Opened in Word Saving/Viewing a Site Report Formatted to Open in Excel Selecting the File Format for ExcelSelect the ‘tabrpt’ file Go to ‘ATC200SiteFiles’ directory Report File Opened in Excel Saving Configurations for Future Use Saving Site Configurations to Hard Drive for Future UseDevice Test, Alarm Status and Device Information Device Status and Test OptionsRetrieving Current Alarm Status Obtaining Device InformationClearing All Alarms on a Device Executing a Self Test Movement for a DeviceSelf Test Results Part Numbering Scheme and Ordering Guide Part Numbering SchemeOrdering Guide Quantity Part Number DescriptionControl System Specifications ElectricalThis page intentionally left blank Bulletin Bulletin Appendix B Antennas For ATC200-Lite Series SystemThis page intentionally left blank