BUILT-IN INSTA LL ATIO N INSTRU CTI ON S
ELECT RICA L REQU IREM ENTS
A
All
IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
WARNING
Do not use an extension cord or
CAUTION
The outlet must be checked by a qualified electrician to be sure that it is wired with the correct polarity. Verify that the outlet provides
WARNING
Always shut power off at the circuit breaker before performing any installation, service or maintenance.
IMPORTANT NOTE: The
PLUMBIN G REQUIRE MENTS
IMPORTANT NOTE: A reverse osmosis system can be used, provided there is constant water pressure of 2.1 bar to 6.9 bar supplied to the unit at all times.
Rough in the cold water supply line using 6 mm OD copper line. The water line should be routed up through the floor within 13 mm from the back wall and no higher than 76 mm off the floor. If you have to come through the wall, make sure the water line is no more than 76 mm from the floor.
Regardless of the routing, allow .9 m of excess copper tubing to remain outside the wall or floor for easy connection to the unit. Locate the water supply line within the shaded area indicated in the Installation Specifications illustration for your specific model on pages
Use an easily accessible
It is not recommended that the ice maker be connected to a softened water supply. Water softener chemicals, such as salt from a malfunc- tioning softener, can damage the ice maker and lead to poor ice quality. If a softened water supply cannot be avoided, be sure that the water softener is well maintained and operating properly.
IMPORTANT NOTE: All installations must meet local plumbing code requirements.
IMPORTANT NOTE: This appliance should be connected to a potable water supply.
UNPACK TH E UNIT
Uncrate the unit and inspect for any damages. Remove the wood base and discard the shipping bolts and brackets that hold the wood base to the bottom of the unit. Remove and discard all packing materials.
IMPORTANT NOTE: Do not discard the kick- plate,
Retract the front leveling legs all the way up to allow the unit to be moved into position more easily. You will extend the leveling legs when the unit is in its final position to reduce the possibil- ity of the unit tipping forward.
IMPORTANT NOTE: The rear levelers must be in their lowest position in order to push the unit back into the rough opening. Therefore, leveling cannot be completed until the unit is in position.
Remove the drain pan from the base of the unit to avoid damage to the drain pan, and allow for proper placement of the appliance dolly.
WARNING
Be sure to secure the door(s) closed before moving the unit.
7