If You Need Assistance
Or Service
This section is designed to help you save the cost of a service call. Part 1 of this section outlines possible problems, their causes, and actions you can take to sofve each problem. Parts 2 and 3 tell you what to do if you still need assistance or service. When calling our
1. Before calling for assistance . . .
Performance problems often result from little things you can find and fix without tools of any kind. Please check the chart below for problems you can fix. It could save you the cost of a service call.
PROBLEM
Nothing will operate
The oven will not operate
Burner fails to light
Burner flames are uneven
Burner flames lift off ports, are yellow, or are noisy when turned off
POSSIBLE CAUSE
The power cord is not plugged into a live circuit with proper voftage.
Range is not properly connected to gas supply.
A household fuse has blown or a circuit breaker has tripped.
Controls are not set correctly.
The flow of combustion a&or ventilation air to the range is blocked.
The electronic control has not been set correctfy.
A delayed start time has been programmed.
The power cord is not plugged into a live circuit with proper voftage.
A household fuse has blown or a circuit breaker has tripped.
Burner ports are clogged.
Burner ports are clogged.
SOLUTION
Plug the power cord into a live circuit with proper voftage. (See Installation Instructions.)
Contact an authorized Roper service technician to reconnect range to gas supply. (See Installation Instructions.)
Replace household fuse or reset circuit breaker.
Reset controls, if needed.
Remove blockage to airflow to and around range.
Refer to pages
Wait for the start time to be reached.
Plug the power cord into a live circuit with proper voftage. (See Installation Instructions.)
Replace household fuse or reset circuit breaker. In case of prolonged power failure, manually light burners (see
page 6).
Clean with a straight pin (see pages 28 and 30).
Clean with a straight pin (see pages 28 and 30). If this fails, call an authorized Roper service technician for service.
Contact an authorized Roper service technician to check air/gas mixture.
32