OPERATION: ....very simple.

1.Fill HOPPERS: REGRIND, NATURAL, COLOR, ADDITIVE: in hoppers as labeled.

If auger feeders are used:

COLOR in RIGHT side feeder,

ADDITIVE in LEFT side feeder.

2. Set THUMBWHEEL switches for percentages desired.

REGRIND, enter as a percent of the entire mix. (xx percent)

COLOR,

as

a

percent

of

the

NATURAL.

(xx.x

percent)

ADDITIVE,

as

a

percent

of

the

NATURAL.

(xx.x

percent)

3.On Controller, turn POWER ON, set STOP, and PAUSE switches UP. Switch MIXER motor DOWN to run for a timed period each cycle.

Unit will now operate automatically to maintain a level of material high enough to cover the sensor.

Use the STOP or PAUSE switches to stop the dispensing of material. Turn POWER off only on final shutdown. Battery-backed RAM ensures all information is retained even with power turned off.

The KEYPAD is only for: 1. MANUAL TESTING.

2.ALTERATION of INTERNAL PARAMETERS

----------------------------------------------------------------------

AFTER SEVERAL DAYS OF PROPER OPERATION:

Save all parameter information to the EEPROM for future retrieval should software problems develop later.

To SAVE all parameter information to the EEPROM:

+---------------------------------------------------

 

 

+

¦ Press:

*

Display will say:

(PASSWORD) ¦

¦ Press:

22222

Display will say:

(P

x.x) ¦

¦ Press:

*

Display will say:

(INSTR --) ¦

¦ Press:

23

Display will say:

(SAVING ) ¦

¦ Wait:

when done,

Display will say:

(P

x.x) ¦

¦ Press: EXIT

Display will say:

(

x.x) ¦

+---------------------------------------------------

 

 

+

IF PROBLEMS DEVELOP:

RETRIEVE this correct copy of the parameters from the EEPROM. This

clears corrupted

data from RAM and corrects most software problems.

+

----------------------------------------

+

¦

Switch:

POWER OFF.

¦

¦

Hold:

the "CE" key down.

¦

¦

Switch:

POWER ON.

¦

¦

Release:

the "CE" key.

¦

¦

 

Display will say ( CLEAR

) ¦

¦

If you do not see ( CLEAR )

¦

¦

on the display, do it again.

¦

+

----------------------------------------

+