Conair GB/ WSB PARAMETERS: Press the PARA key to display the, table, of operating, Para, There

Models: GB/ WSB

1 118
Download 118 pages 8.17 Kb
Page 34
Image 34

A new setting may be entered at this time by keypad if so desired. (CE will cancel entry before last digit is entered.) Settings entered by keypad CAN NOT BE ALTERED by the thumbwheel switches. After entering a setting by keypad, verify this by rotating the appropriate thumbwheel switches. An LED will light indicating that the internal setting being used by the computer does not match the thumbwheel switches.

The display of a setting followed by pressing the "CE" key, will revert that setting back to thumbwheel control and will also exit the sequence. EXIT will exit the sequence.

This function will positively fix the settings so that thumbwheel switches have no control and no one can change them without authorization. An LED will light indicating this override condition. The LED will be lit ONLY when the thumbwheel setting does not match the internal setting.

To allow the operator the ability to stop running this component, a setting of all ZEROS (00.0) is still accepted as valid and will override any setting that has been entered by keypad. If you do not want this override option, enter a 1 as the first digit in the SE parameter. See PARAMETERS, _SE.

To later return to thumbwheel control, use the same procedure as above except instead of entering a setting, press the "CE" key when you see the setting displayed.

PARAMETERS: Press the PARA key to display the

table

of operating

(PARA)

parameters that reside in memory.

There

are more then 60

 

parameters, and each successive press of

the key displays

 

the next parameter in the table. Pressing

the "*" key

 

allows you to back-up in the table. You

may change a

 

parameter by entering a new number

over the old one. CE

 

will cancel a number entry before the last

digit is entered.

 

All parameters are fully explained

several

pages forward in

 

this manual. EXIT will exit the sequence.

 

STAR FUNCTIONS.

*02 This flag for EXTRUSION and YIELD control.

Press (*,0,2) to turn on

Extrusion

or Yield control.

The default display is

(

OFF).

 

Press * to toggle this

flag to (

RATE ), (EXT CTRL), or

(YLD CTRL).

 

 

 

If you are using our EXTRUSION or YIELD control software to control your extruder, refer to our EXTRUSION CONTROL instruction booklet for complete information.

If you simply want to view throughput continuously on

the

blender display, set this

option to (

RATE ). This

will

Page

35

 

 

Page 34
Image 34
Conair GB/ WSB PARAMETERS: Press the PARA key to display the, table, of operating, Para, parameters that reside in memory