Conair GB/ WSB Parameters, WEIGHTS are always expressed as GRAMS, RECIPE key is for, FAST key

Models: GB/ WSB

1 118
Download 118 pages 8.17 Kb
Page 43
Image 43

PARAMETERS

All WEIGH SCALE BLENDER controllers operate according to certain internal PARAMETERS. Because customer requirements vary widely, we have made over 60 parameters accessible for change through the keypad.

BRIEF explanations are given first. FULL information is given in the section that follows.

NOTE: Values shown here are initial ROM values of a model 220. Initial values for other models are listed at the end of this section.

Parameters are five digits, with leading zeros added.

TIMES are expressed as seconds, minutes, or interrupts. (244 interrupts = 1 second).

WEIGHTS are always expressed as GRAMS.

100 and 200 models use tenths of grams: (xxxx.x). (00010 = 1 gram)

400, 900, and 1800 models; full grams: (xxxxx). (00050 = 50 grams)

PERCENTS are expressed in tenths for settings (0xxx.x),

and full percents for other percentage references (00xxx).

======================================================================

PARAMETER LIST - BRIEF EXPLANATIONS

FLG 00000 turns on the RECIPE, BATCH, FAST, and TAG keys.

These four keys will NOT WORK unless you set this parameter.

The

RECIPE key is for

storing up to 99 recipes.

The

BATCH key allows for filling a barrel or gaylord.

The

FAST key

allows a

higher output mode.

The

TAG key adds certain information to all printouts.

RPO 00000

Pulsed Output,

timing of ON/OFF pulses.

NPO 00000

(Reg,

Nat, Col, Add).

CPO 00000

Set only for Micro Pulse equipped slide gates.

APO 00000

 

 

 

MPO 00010

Pulsed output to the mixer motor

RAL 00000

Last digit = number of retries before ALARM.

NAL 00004

00001

to 00009

= sound alarm, hold process.

CAL 00004

00011

to 00019

= sound alarm, continue process.

AAL 00004

00000

= no alarm, no retries.

These parameters set ALARM

functions.

 

 

When material runs out,

or

does

not

dispense

fully, these flags

instruct the

controller

what to

do.

Default

settings shown

are

for

Natural,

Color, and

Additive to

alarm, but not Regrind.

 

MIX 00015

MIX TIME

 

 

 

 

 

 

This parameter times how long the MIX motor runs in seconds.

Page 44