Press RCP

to

look at

another recipe. Display = (GET

__).

Enter 2

digits to retrieve

one of 99 recipes.

 

 

Display

will

flash through

the current stored data:

 

(RCP

__), (R =

xx

), (C

= xx.x), (A = xx.x), (*TO LOAD)

Press *

to LOAD this

recipe into memory.

 

 

Routine will exit

automatically.

 

 

Press RCP

or

EXIT to

return to the display (GET

__).

Press RCP

or

EXIT again to

exit.

 

 

To SAVE

a

RECIPE

you

must be in the PROGRAM mode.

 

 

If you press

RCP

key

again

after display of (GET

 

__),

display

says

(SAVE

__).

Enter 2 digits, display will say

(SAVING

 

).

The

current settings are saved into memory

under the

recipe

number you have entered. These are

normally the

THUMBWHEEL switch settings.

 

 

CAUTION: If settings have been entered by KEYPAD or RECIPE, then these are the ones that will be saved. Therefore, when saving a recipe, be certain that no other recipe is currently loaded, and that no keypad-entered settings are currently loaded. The lower right corner of 3 LEDs should be off indicating thumbwheels are being read.

To clear a stored recipe, set all thumbwheel switches to zero and enter these zero settings into the recipe location.

Routine will EXIT automatically.

EXIT will exit at any time.

When a RECIPE is loaded, three LEDs, (R, C, A, Locked out) light indicating that the thumbwheel settings do not represent the settings that are being run by the controller. Whenever internally stored settings are not the same as the thumbwheel settings, these three LEDs light to indicate this condition. These LEDs correspond to REGRIND, COLOR, and ADDITIVE settings respectively.

NOTE: To allow the operator the ability to stop running any single component, a thumbwheel setting of all ZEROS (00.0) can be accepted as valid to override any setting entered by a Recipe. If you want this override option, enter a 0 (_SE 0xxxx) as the first digit in the SE parameter. The default entry of 1 (_SE 1xxxx) indicates the override option is turned off. See PARAMETERS; SE.

BATCH:

This key allows you to blend a PRE-SELECTED

WEIGHT of

 

(BTCH)

material, and then STOP running and sound the ALARM.

The

 

process may also be programmed to sound the

alarm but

 

 

continue running. Since each cycle will always blend

a full

 

weigh bin amount, the total amount blended may exceed

the

 

target batch weight by up to one cycle's blend weight.

 

 

This key is NOT FUNCTIONAL unless the last digit of the

 

"FLG" parameter is set to 1 or 2 (xxxx1). To do this, see

 

the SOFTWARE MAINTENANCE section, PARAMETER

TABLE, "FLG".

 

The ALARM SILENCE button on the side of the

controller, is

 

Page 28

 

 

Page 27
Image 27
Conair GB/ WSB manual Save, Btch, Table, Flg