Conair GB/ WSB JOG 03030 Mix blade JOG count and interval, No change is required, COLOR or, When

Models: GB/ WSB

1 118
Download 118 pages 8.17 Kb
Page 44
Image 44

JOG 03030 Mix blade JOG count and interval

This parameter sets how many jogs will occur and how often.

FCV 00006 TIME the Flow Control valve delays before opening (sec.).

This parameter holds each batch in the mix chamber for a time to assure mixing. This is only for units equipped with the optional flow control valve under the mix chamber.

DTI 00006 Weigh bin dump TIME at end of cycle. (seconds)

This parameter sets the maximum open, or dump time for the weigh bin. No change is required.

KDF 00010 Maximum variation in GRAMS between two consecutive weight

WDF 00010 readings for reading to be accepted. (x or x.x)

KDF controls sensitivity of weight readings during calibration of load cells. No change is required.

WDF controls the sensitivity of weight readings during normal operation. If excessive vibration interferes with weight readings you may have to increase this number.

BER 00200 Excess GRAM weight before dispense is aborted.

This parameter controls sensitivity of the emergency "bailout" routine that prevents overfilling of the weigh bin.

No change is required.

CXT 00000 Move decimal left on color and additive settings. AXT 00000

These parameters allow entry

of less then (00.1) percent for

COLOR or

ADDITIVE.

 

 

 

 

 

When

set

to

"00010" settings

are

read

as

X.XX

percent.

When

set

to

"00100" settings

are

read

as

.XXX

percent.

ROC 00000 These three parameters help control regrind usage. ROV 00000

RHL 00000

ROC indicates the PERCENT of REGRIND that will be treated as natural when COLOR and ADDITIVE dispenses are calculated. This adds some color or additive to your regrind.

ROV is for closed loop fully automatic reprocessing of regrind scrap. This parameter will detect when more regrind is being produced than consumed, and override the current setting to use a higher amount. This helps prevent material backing up in your grinder.

RHL has effect only if level sensors are added to your unit to detect material level in the regrind hopper. These level sensors can alter regrind percent usage.

FUL 20000 Full batch weight, determined by weigh bin size.

MAX 30000 Maximum GRAM weight the software will target.

FUL is the target weight that is blended each cycle. Change only