for extremely

fluffy

or

very heavy

material.

 

MAX prevents overflowing

of

the weigh bin. It is

reset

automatically

if the

FUL parameter

is changed.

TH 01000 The highest and lowest acceptable TARE weights for

TL 00500 blend cycle to start. (full or tenth grams)

TL prevents starting with the weigh bin out of place. No change is required.

TH prevents starting with a full weigh bin. Change TH only if clumps of material hang up in the weigh bin.

PRT 00000 MINUTE interval between automatic print of TOTALS.

This parameter will cause your system to PRINT MATERIAL TOTALS automatically. A printer must be connected.

RSE 01000

Upper SETTING limits for thumbwheels (0xxx.x).

CSE 01000

Settings greater than limit are held to limit.

ASE 01000

"01000" = 100%.

RLO 00050

Lower SETTING limit for REGRIND (0xxx.x).

_SE

parameters SET UPPER LIMITS to the thumbwheels. For color

 

and additive, lower settings may help ensure expensive

 

material is not wasted.

RLO

sets a LOW limit of 5 percent to the REGRIND setting.

DLY 00488

Delay before cycle start. (interrupts)

This parameter is the time that the sensor must be uncovered before a cycle will begin.

LT1 00000 Loader #1 time. (seconds)

LT2 00000 Loader #2 time.

These are timers for loaders. Since loader outputs are not yet available, leave them set to zero.

RPT 00000 Percent of target to reduce first try dispense. NPT 00000

CPT 00000

APT 00000

These can increase the accuracy of slow dispense devices ONLY, like augers, and micro pulse valves.

RWT 26000

WT/TI = the rate that will

be used for calculating the

RTI 00976

next dispense time.

 

NWT 26000

WT = the Weight portion of

the dispense rate, calculated

NTI 00976

such that WT/TI equals the average of the last two

CWT 10240

actual dispense rates.

 

CTI 31232

TI = the TIME portion of the dispense rate. (interrupts)

AWT 10240

 

 

ATI 31232

 

 

These change AUTOMATICALLY during

normal operation.

They are Weight and Time portions

of the flow rate calibration.