Conair GB/ WSB manual Specifications, Appendix B

Models: GB/ WSB

1 118
Download 118 pages 8.17 Kb
Page 104
Image 104
Manual background

TPS014/1199

SPECIFICATIONS

GRAVIMETRIC BATCH BLENDERS AutoWeigh GB1840 and 1860 Models

FEEDER LOCATIONS

DC

4

C 2

1

3

AB

Manual background B Manual background

TOP VIEW GB1840

CONTROL

D

B

Manual backgroundManual background C Manual background

A

C

FEEDER LOCATIONS

C

D

 

C

8

7

4

 

1

2

3

 

A

B

B

 

 

 

 

TOP VIEW GB1860

NOTE: Any one of the feeders (A,B,C or D) can be designated position 5 or 6.

E

F

FRONT VIEW

SIDE VIEW

SIDE VIEW

GB1840/GB1860

GB1840

GB1860

MODELS

 

 

 

GB1840

GB1860

Performance characteristics

 

 

 

 

Batch size lbs {g}

 

 

 

39.7 {18000}

39.7 {18000}

Maximum throughput lbs/hr {kg/hr}*

4114 {1870}

2566 {1166}

Bin Capacity - Main Ingredient

ft3 {liter}

6.7 {189.7}

3.8 {107.6}

Bin Capacity - Minor Capacity

ft3 {liter}

3.8 {107.6}

3.8 {107.6}

Maximum number of materials

 

 

8

10

Number of discharge valves

 

 

4

6

Number of additive feeders

 

 

up to 4

up to 4

Control software (# of components)

4 or 12

12

Dimensions inches {mm}

 

 

 

 

A - Height above mounting plate

93 {2362.2}

93 {2362.2}

B - Width

 

 

 

56 {1421.4}

56 {1421.4}

C - Depth

 

 

 

34 {863.6}

34 {863.6}

D - Controller height

 

 

 

11.25 {285.75}

11.25 {285.75}

E - Controller width

 

 

 

12.25 {311.15}

12.25 {311.15}

F - Controller depth

 

 

 

8.19 {208.03}

8.19 {208.03}

Weight lbs {kg}

 

 

 

 

 

Installed

 

 

 

730 {331}

730 {331}

Shipping

 

 

 

850 {385.5}

850 {385.5}

Voltage Running load amps‡

 

 

 

 

110V/1 phase/60hz

(control)

 

 

0.3

0.3

220V/1 phase/60hz

(mixer)

 

 

8.2

8.2

220V/1 phase/60hz

(control)

 

 

0.2

0.2

220V/1 phase/60hz

(mixer)

 

 

8.2

8.2

220V/1 phase/50hz

(control)

 

 

0.2

0.2

220V/3 phase/50hz

(mixer)

 

 

4.4

4.4

400V/3 phase/50hz

(mixer)

 

 

2.2

2.2

Compressed air requirements

 

 

 

 

Discharge valves

 

 

80 psi @ 0.2 ft3/min {5.5 bars @ 0.09 liters/sec}

 

 

 

 

1/4 in. NPT fitting

 

Maximum loader sizes §

 

 

 

 

Number of 20 inch loaders

 

 

2

3

Number of 15 inch loaders

 

 

4

6

 

 

 

 

 

 

MOUNTING INTERFACE

 

(4) 9/16 in. {14.3 mm}

IB04

diameter bolt holes

4 in. {101.6 mm}

8 in. {203.2 mm}

diameter

square bolt pattern

through hole

 

14.5 in.

16 in.

{406.4 mm}

{368.3 mm}

 

15 in. {381 mm}

20 in. {508 mm}

SPECIFICATION NOTES

*Maximum throughput rates are based on 35 lb/ft3 pel- letized material and using all dispense valves. Use of feeders for minor ingredients will reduce this rate.

Refer to the selection guide for more specific through- put information.

Feeders will increase width dimensions. Please refer to feeder specification.

Each auger feeder requires an additional 1 amp @ 120V or 0.5 amp @ 240V.

§Maximum loader sizes may be used only when the loader is adjacent to loaders of a smaller diameter.

One Conair Drive Pittsburgh, PA 15202 412-312-6000 FAX 412-312-6227 www.conairnet.com