Conair GB/ WSB Special Totalizer Function, To reset the, totals to, zero, First, stop, operation

Models: GB/ WSB

1 118
Download 118 pages 8.17 Kb
Page 95
Image 95

SPECIAL TOTALIZER FUNCTION

A special function is available that allows throughput TOTALS to be displayed at all times. This flag is for TOTALIZER models only.

When set, the display will continuously display the total amount of material that has passed through the unit since the total fields were last cleared. When the unit is functioning as a totalizer, this is the information that is most meaningful.

Since totalizers do not blend, this flag also causes all settings to be set to zero whenever power is turned on.

To reset the

totals to

zero:

 

First,

stop

operation

by switching to

"STOP END OF CYCLE".

Next,

switch to "IMMEDIATE PAUSE".

 

Last,

press "ALARM SILENCE" to clear

the totals.

We may have already

set this flag.

 

 

 

If we did not, the sequence of keystrokes is as follows:

 

 

+

------------------------------------------------------

 

 

 

+

¦

Press:

*

Display will say:

(PASSWORD)

¦

¦

Press:

22222

Display will say:

(P

x.x)

¦

¦

Press:

*47

Display will say:

(BLENDER )

¦

¦

Press:

*

Display will say:

(TOTALIZE)

¦

¦

Press:

EXIT

Display will say:

(P

x.x)

¦

¦

Press:

EXIT

Display will say:

(

x.x)

¦

+

------------------------------------------------------

 

 

 

+