Detailed explanations are given on the pages that follow.

AUTOMATIC OPERATION MODE: (normal operation on power up) These keys are operational in this mode.

VIEW: View Data: date, time, cycles, and lbs of Reg, Nat, Col, Add. Press VIEW,* to print all data. At end press 00 to clear data.

RCP: Enter and retrieve stored RECIPES.

BTCH: Blend a preset weight, fill a container and stop. View/Enter Target Wt., Cur. Portion, Total, Batch Count. CE=clear

FAST: Increase Output. Run rapid FAST cycles after a weighed cycle. Press * to toggle this function on or off.

TAG: Tag a Work Order and Operator number to all reports.

EXIT: Operational in ALL MODES. Press to EXIT any and all sequences.

CE: Press to display the "raw signal" weight readout for 3 seconds.

MANUAL MODE: to enter press: "*" then (11111) or your own password. These additional keys are operational.

SET: Observe current settings, set by thumbwheel or keypad.

OPER: Operate all devices manually; open and close valves.

TIME: Operate devices for a timed period.

CAL: Operate devices for a preset time period to learn the rate. NOTE: With above four keys also press one DEVICE key:

NAT, REG, COL, ADD, DUMP, ALARM, MIX, or HOLD. ZERO: Zero the tare weight with the bin empty.

FULL: With bin loaded, enter gram weight to calibrate load cells.

*00 Clear DATA fields.

*99 Enable calibration of load cells.

PROGRAM MODE: to enter press: "*" then (22222) or your own password. MANUAL operations plus these additional keys are operational.

SET: Enter settings using keypad; locks out thumbwheel use.

PARA: View or change system constants and parameters.

STAR FUNCTIONS: Press * and two numbers for the following functions:

*02

Extrusion

and Yield Control.

*66

GB/WSB I.D. number (1-255).

*05

Inhibit

table clearing.

*69

Regrind as second natural.

*11

DATE -

TIME, real-time clock.

*71

Color percent of blend.

*12

Move table from ROM to RAM.

*72

Additive percent of blend.

*23

Move from

RAM to EEPROM.

*74

Stop, alarm MAX wt exceeded.

*32

Move from

EEPROM to RAM.

*75

Alarm on weight drop.

*25

ROM OK

flag, "CE" to clear.

*77

Print parameters.

*33

Special Alarms.

*78

Change program mode PASSWORD.

*44

End cycle

- bin full.

*82

Precision Ratioing.

*45

Change

MANUAL mode password.

*87

VOLUMETRIC operation.

*47

Totalizer

flag.

*88

Print display readout.

*52

Double

dump weigh bin.

*89

Select pounds, kilos.

*54

Print cycle information.

*98

Display raw weight number.

*57

For Liquid Color PIAD system

 

 

Use "*" key to select readout or toggle flags ON or OFF.

Page 26

Page 25
Image 25
Conair GB/ WSB manual Date, Rom Ok