Detailed explanations are given on the pages that follow.
AUTOMATIC OPERATION MODE: (normal operation on power up) These keys are operational in this mode.
VIEW: View Data: date, time, cycles, and lbs of Reg, Nat, Col, Add. Press VIEW,* to print all data. At end press 00 to clear data.
RCP: Enter and retrieve stored RECIPES.
BTCH: Blend a preset weight, fill a container and stop. View/Enter Target Wt., Cur. Portion, Total, Batch Count. CE=clear
FAST: Increase Output. Run rapid FAST cycles after a weighed cycle. Press * to toggle this function on or off.
TAG: Tag a Work Order and Operator number to all reports.
EXIT: Operational in ALL MODES. Press to EXIT any and all sequences.
CE: Press to display the "raw signal" weight readout for 3 seconds.
MANUAL MODE: to enter press: "*" then (11111) or your own password. These additional keys are operational.
SET: Observe current settings, set by thumbwheel or keypad.
OPER: Operate all devices manually; open and close valves.
TIME: Operate devices for a timed period.
CAL: Operate devices for a preset time period to learn the rate. NOTE: With above four keys also press one DEVICE key:
NAT, REG, COL, ADD, DUMP, ALARM, MIX, or HOLD. ZERO: Zero the tare weight with the bin empty.
FULL: With bin loaded, enter gram weight to calibrate load cells.
*00 Clear DATA fields.
*99 Enable calibration of load cells.
PROGRAM MODE: to enter press: "*" then (22222) or your own password. MANUAL operations plus these additional keys are operational.
SET: Enter settings using keypad; locks out thumbwheel use.
PARA: View or change system constants and parameters.
STAR FUNCTIONS: Press * and two numbers for the following functions:
*02 | Extrusion | and Yield Control. | *66 | GB/WSB I.D. number | |
*05 | Inhibit | table clearing. | *69 | Regrind as second natural. | |
*11 | DATE - | TIME, | *71 | Color percent of blend. | |
*12 | Move table from ROM to RAM. | *72 | Additive percent of blend. | ||
*23 | Move from | RAM to EEPROM. | *74 | Stop, alarm MAX wt exceeded. | |
*32 | Move from | EEPROM to RAM. | *75 | Alarm on weight drop. | |
*25 | ROM OK | flag, "CE" to clear. | *77 | Print parameters. | |
*33 | Special Alarms. | *78 | Change program mode PASSWORD. | ||
*44 | End cycle | - bin full. | *82 | Precision Ratioing. | |
*45 | Change | MANUAL mode password. | *87 | VOLUMETRIC operation. | |
*47 | Totalizer | flag. | *88 | Print display readout. | |
*52 | Double | dump weigh bin. | *89 | Select pounds, kilos. | |
*54 | Print cycle information. | *98 | Display raw weight number. | ||
*57 | For Liquid Color PIAD system |
|
|
Use "*" key to select readout or toggle flags ON or OFF.
Page 26