_SE (This might be useful)

_SE is the upper SETTING limits for the thumbwheel switches. This allows a reasonable cap to be set for each component so that an operator cannot accidentally set the controls to an excessively high setting. For color and additive, these limits will ensure that expensive material is not wasted. Thumbwheel settings that are greater than the limit are held to the limit.

EXAMPLE: If the highest color usage in your plant is 6%, you may enter this upper limit in the parameter table. Since settings are stored as 1/10s of percent (##.#), the parameter would be:

CSE 00060

Color thumbwheel settings above 060 will be held to 6 percent.

NOTE: If

you wish to positively fix the settings so that the

thumbwheel

switches have no control

and no one can change them without

authorization,

you may do this by using the KEYPAD to enter any or

all

settings.

To do so:

 

 

 

 

 

+---------------------------------------------------

 

 

 

+

 

¦ Press:

*

Display will say:

(PASSWORD)

¦

 

¦ Press:

22222

Display will say:

(P

x)

¦

 

¦ Press:

SET

Display will say:

(SETTING )

¦

 

¦ Press:

COL (or ADD or REG)

 

 

¦

 

¦

 

Display will say:

(C = xx.x)

¦

 

¦ Enter:

New setting

 

 

¦

 

¦

 

 

 

 

¦

 

¦ Press:

EXIT

Display will say:

(P

xxxxx)

¦

 

+---------------------------------------------------

 

 

 

+

An LED will light indicating this override condition. This occurs only when the thumbwheel does not match the internal setting.

To later return to thumbwheel control, use the same procedure as above except instead of entering a setting, press the "CE" key when you see the setting displayed.

The operator may still prevent running this component by entering a setting of all ZEROS (00.0). This will override any setting entered by the keypad. If you do not want this override option, enter a 1 as the first digit in the SE parameter. (_SE 1xxxx)

======================================================================

RLO (probably no need to ever change this)

RLO is the lower limit for SETTING the regrind thumbwheel switches. Settings lower than this number will be held to the low limit. Air operated dump valves are not intended to dispense very small quantities. We have set RLO at the factory to 5 percent (00050) allowing a minimum dispense of 5% or about 100 grams.

======================================================================

DLY (consider changing if mixing is a problem)

DLY is the TIME the mix chamber level sensor must be uncovered before a cycle begins. The sensor must be uncovered without

Page 58

Page 57
Image 57
Conair GB/ WSB manual Setting