Three (3) operation Modes are available; AUTOMATIC, MANUAL, PROGRAM.

KEYPAD - AUTOMATIC OPERATION MODE

This is the NORMAL operating mode. When power is turned on, the unit is in this mode. Automatic dispensing occurs ONLY in this mode. The AUTOMATIC mode is indicated by the ABSENCE of the letter "P" or "M" at the left end of the display.

Only the VIEW, RECIPE, BATCH, FAST, TAG, *, CE, and EXIT keys are available in this mode.

These keys operate BETWEEN cycles only or when the PAUSE switch is on. To stop between cycles, use the "OFF AT END OF CYCLE" switch.

VIEW DATA: Press to display the CURRENT Date and Time, LAST CLEARED

(VIEW) date and time, and stored material usage data. Six totals are available: (in Pounds, Kilos, Grams, or Ounces)

Number of CYCLES that have occurred:

(CY= #####)

Weight of REGRIND that has been dispensed:

(R = #####)

Weight of NATURAL:

(N = #####)

Weight of COLOR:

(C = #####)

Weight of ADDITIVE:

(A = #####)

Total weight of ALL materials:

(T = #####)

Each successive press of the VIEW key displays the next total. The last displayed line will say (00=CLEAR) for 5 seconds. During this time, you may press 0,0 to clear the data. Waiting 5 seconds or pressing any other key will exit the sequence. When the sequence is exited, normal automatic operation resumes. These totals may be displayed as pounds, grams, kilograms, or ounces by a selection procedure explained later (*89).

Press the VIEW key once followed by the "*" key to cause all information to be sent to the printer (if available). To then clear the data, press 00 within 5 seconds. Press any other key or, wait 5 seconds, to continue the process without clearing the totals.

RECIPE:

This key

allows you to LOOK at,

RUN,

and SAVE RECIPES.

(RCP)

To SAVE a recipe you must be in

the PROGRAM mode. Recipes

 

are thumbwheel

switch settings.

100

recipes may be stored,

 

numbered

00 to

99.

 

 

This key is NOT FUNCTIONAL unless the 3rd digit of the "FLG" parameter is set to 1 (xx1xx). To do this, see the SOFTWARE MAINTENANCE section, PARAMETER TABLE, "FLG".

In normal

Automatic

mode:

Press RCP key.

If no

RECIPE

is

currently

in

use,

display says (GET

__).

If a

RECIPE

is

currently

in

use then display

will flash through

the current

stored data:

 

 

 

 

 

 

 

 

 

(RCP

__), (R

=

xx ),

(C

= xx.x), (A = xx.x)

 

 

Press CE to CLEAR CURRENT RECIPE and return to thumbwheels.

Page 27

Page 26
Image 26
Conair GB/ WSB manual Keypad Automatic Operation Mode, Recipe, Run, Rcp