CHANGING PARAMETERS

To change a PARAMETER, the sequence of keystrokes is as follows:

+--------------------------------------------------------------

 

 

 

 

+

¦ Press:

*

Display

will say:

(PASSWORD)

¦

¦ Press:

22222

Display

will say:

(P

x.x)

¦

¦ Press:

PARA

Display

will say:

(RRAxxxxx)

¦

¦ Press:

PARA

Press again to walk

FORWARD through list. ¦

¦ Press:

*

to BACK

UP in the list.

 

¦

¦

 

 

 

 

 

¦

¦

When the PARAMETER you want is displayed,

¦

¦

enter a new setting using the

number keys.

¦

¦

You must enter 5 digits. Use leading zeros.

¦

¦

 

 

 

 

 

¦

¦ Press:

EXIT

Display

will say:

(P

x.x)

¦

+--------------------------------------------------------------

 

 

 

 

+

Additional information can be found in the KEYPAD section.

SAVING PARAMETERS in the EEPROM

If the changes you have made are PERMANENT, SAVE them in the EEPROM.

Sometimes during normal operation, electrical noise or RF (Radio Frequency) noise will corrupt the processor memory. It may be necessary to do a CLEAR to fix this problem.

A "CLEAR" will clear all data from memory and replace it with information stored in the EEPROM.

So it is a good idea to have an exact copy of RAM stored in the EEPROM for just such an emergency.

To copy ALL PARAMETERS into the EEPROM, the sequence of keystrokes is as follows:

+---------------------------------------------------

 

 

+

¦ Be in PROGRAM mode, first 2 steps above:

¦

¦

 

Display will say:

(P

x.x) ¦

¦

 

 

 

¦

¦ Press:

*

Display will say:

(INSTR --) ¦

¦ Press:

23

Display will say:

(SAVING ) ¦

¦ Wait:

when done,

Display will say:

(P

x.x) ¦

¦ Press:

EXIT

Display will say:

(

x.x) ¦

+---------------------------------------------------

 

 

+

With this done,

all correct

Parameters may be restored from EEPROM to

RAM at any time

by doing a CLEAR.

 

 

To do a CLEAR, hold the "CE" key down when turning POWER ON.