Conair GB/ WSB Cnc Anc, Crp Arp, Crd Ard, RLA 00020 Lag TIME before dumping ACTUALLY starts, Page

Models: GB/ WSB

1 118
Download 118 pages 8.17 Kb
Page 46
Image 46

RMI 00001 Minimum valid dump rate GRAMS/sec. (full or tenth grams)

NMI 00001 Error correction is bypassed when dispense rate is lower. CMI 00001

AMI 00001

On power up, these are always set to 1. After several consistent cycles, they are reset to 80 percent of actual flow rate. These prevent excessive swings in flow rate calculations if material is running out.

RNC 00050 Allowable GRAM error within which NO correction is made. NNC 00050

CNC 00010

ANC 00010

This is the acceptable error range for each component to prevent hunting. They adjust automatically over an extended time period to match the flow characteristics of each material.

RRP 00010 PERCENT shortage error that will force a retry. NRP 00010

CRP 00010

ARP 00010

RRD 00500 GRAM weight shortage error that will force a retry. NRD 00500

CRD 00050

ARD 00050

Both RP and RD limits must be met before system will advance to the next component. Retries occur until both conditions are met.

RLA 00020 Lag TIME before dumping ACTUALLY starts.

NLA 00020 (mechanical response time, interrupts)

CLA 00012

ALA 00012

These parameters state the lag time between when a device is signaled and when it actually begins to operate.

Change ONLY if you change to non-standard equipment.

PRC 00010 Maximum allowable PERCENT rate change per cycle.

This prevents excessive swings in flow rates. Do not change.

STL 00244 Dispense settle TIME before a weight reading is taken.

The time (interrupts) allowed for material to SETTLE in the weigh bin before a weight is taken. Lengthen only to slow the next cycle start, thereby lowering the pile of material in the mix chamber, and, in some cases, improving mixing.

LCL 00027 LOAD CELL limits, low slope, high slope, frequency, zero.

LCH 00039 DO NOT CHANGE except for different weight load cells. LCF 00079

LCZ 00583

These parameters relate to the characteristics of the LOAD CELLS on your blender. DO NOT CHANGE THEM.

Page 47

Page 46
Image 46
Conair GB/ WSB manual Cnc Anc, Crp Arp, Crd Ard, RLA 00020 Lag TIME before dumping ACTUALLY starts, Cla Ala, Page