CHECK OUT PROCEDURE

As you go through this procedure, if WHAT SHOULD HAPPEN, doesn't happen, see the next section, DIAGNOSTICS, for what to check.

NOTE: 100 and 200 series models (3K load cells), display all weight

readings in 1/10 grams ( x.x). 400, 900, and 1800 series models (10K load cells) display in FULL grams, no decimal.

On this page we show all weight readings WITH a decimal point.

Start with NO MATERIAL in any hoppers. Be sure an AIR SUPPLY is connected.

Place ALL switches DOWN; POWER (on front); STOP and PAUSE (on left).

PROCEDURE:

WHAT SHOULD

HAPPEN:

.

PLUG IN CONTROLLER.

Nothing should happen.

 

 

Air pressure should be holding ALL valves CLOSED.

 

This means all air cylinders are extended. If any

 

slide gate or flap is open, air lines are

 

reversed.

 

 

TURN POWER ON.

Display should show ( FOUR

), software type,

 

followed by

version date (V=50920A),

 

followed by

the check sum number (CKS xxxx),

 

followed by

(ROM OK ),

 

 

followed by

(RAM = 8K),

 

 

followed by

(MODEL220) or MB, 140, 131, 122, 240,

 

420,

440, 940, 1840. (NOTE:

The MODEL

 

number must match your unit, except for

 

the zero. If not see below.)

 

 

followed by (

0.0),

 

 

 

followed by the actual weight of material in the

 

bin. This number should

be close to 0, plus or

 

minus several

grams (

20.0) to (-

20.0).

AT THIS POINT:

Be sure the display is in tenths of grams,

 

or full grams

depending on your model.

 

If the weight display is NOT correct, or the MODEL number is not correct;

see SELECTING CORRECT MODEL, next section.

TOUCH WEIGH BIN VERY LIGHTLY.

Display should update the weight every second reflecting the light pressure that you are exerting on the bin.

PRESS "*" KEY

Display will say (PASSWORD)

 

PRESS "22222"

(2 key five times) (entering

the Program mode)

 

2's will be displayed as you

enter them.

 

Display will show (P

x.x)

when done.

PRESS "OPER" KEY

Display will say (OPERATE )

 

 

Page 11

 

 

Page 10
Image 10
Conair GB/ WSB Procedure What should Happen Plug in Controller, Turn Power on, AT this Point, Touch Weigh BIN Very Lightly