IMPORTANT: work cycles and modes can only be selected when the appliance is ON (LED on push - button 6 off)
IMPORTANT: The appliance will automatically defrost if coil temperature falls below 45˚F. It will not go into defrost during a chill or freeze cycle. When it is in defrost a new cycle can not be initiated until defrost is complete.
5.2 SOFT BLAST CHILLING BY TEMPERATURE (pre-cooked, hot foods)
• To select this cycle, press | +38ο | (relative LED lights up), then press | |||||
| |||||||
to select the temperature mode (LED 5A |
| on) |
|
|
| ||
• Insert the core probe into the core of the product to be chilled. |
| ||||||
• Start up the cycle by pressing | . LED 5A | and those related to the | |||||
pressed illuminate throughout the cycle, while LEDs 12 | flash. |
| |||||
• Display 15 | indicates the maximum blast chilling time (starting temperature to end of the | ||||||
blast chilling temperature (factory setting 90 minutes). |
|
| |||||
• The temperature measured by the core probe is shown by display 16 | οC . | ||||||
• The instrument timer starts the countdown of the maximum blast chilling time as soon as the temperature | |||||||
measured by the core probe falls below the temperature of +149°F / +65°C (the dot at | |||||||
the bottom right of display 15 | flashes). |
|
|
| |||
• During the blast chilling cycle, the air temperature is around +32°F / 0°C and may get as low as | |||||||
This function is designed to guarantee uniform cooling of the product, preventing frost formation | |||||||
on the surfaces. During the blast chilling cycle, the compressor may therefore stop and restart, | |||||||
depending on the reading of the compartment temperature probe. |
| ||||||
• The blast chilling phase ends only when the core probe (inserted in the product core) indicates |
that the set blast chilling temperature (+38°F / +3°C) has been reached as signalled by an intermittent
beep for a minute. During the beep, LEDs 13 | and 14 |
|
|
|
|
| flash. |
| ||
Display 16 |
| οC indicates the temperature inside the compartment, while display 15 | shows blast | |||||||
| ||||||||||
| ||||||||||
chilling time reset to zero. |
|
|
|
|
|
|
|
|
•If at the end of the maximum blast chilling interval the core probe continues to display a temperature higher than the value for the end of blast chilling, the displays will indicate an alarm for
excessively long chilling (ALL 14) alternating with the temperature and time; at the same time, the alarm beep will be activated.
The blast chilling cycle continues until the end chilling temperature has been reached; display 15 counts back the minutes remaining until the end of the cycle.
Press