Delfield™®
Unit |
|
|
| 30.00 | |
Condensing |
|
|
| 35.00 | |
|
|
|
| ||
|
| 48.00 |
| 36.00 | |
| Ambient Operating Limits: |
| |||
Remote | Note: The Delfield Blast | Chiller/Shock Freezer is wired independently of the remote | |||
condensing unit. No interconnecting wiring is required between the blast chiller | |||||
| |||||
| and the condensing unit. All condensing units have units have crankcase heaters. | ||||
| Condensing unit control systems are provided wired from the factory. Field | ||||
| Connection is made by connecting supply power to the compressor contactor. | ||||
| Outdoor condensing unit applications require the use of an optional UL listed hood, | ||||
| delfield P/N CUHOOD, for protection from the elements. Water cooled units are not | ||||
| recommended for outdoor installation. |
|
| ||
Freezer | Interconnecting piping, curbs or other mounting methods and refrigerant are not | ||||
included. Installation must be made by a qualified refrigeration technician. Piping runs | |||||
Refrigerant |
|
| 404A | ||
| of greater than 100 feet require consultaion with the factory. |
| |||
|
| T40 |
|
| |
|
| Delfield | Model#: T40CU |
| |
Chiller/Shock |
|
|
| 6 HP Compressor | |
| Compressor and Capacity | 24,150 BTUH @ | |||
|
| ||||
| Compressor and wiring |
|
| @ | |
|
|
| 208/230V/60Hz/3Ph | ||
|
|
|
| ||
|
| Condensing Unit Wiring | Max Fuse Size: 60A | ||
|
|
|
| Max Circuit Ampacity:42.3A | |
|
| High Pressure Switch | Set Point: 450 psig, 380 psig | ||
| Control System | Low pressure switch | Set Point: 25psig, Range = 15in to 100psig | ||
|
| Oil Pressure Differential Switch | Sensotronic Oil Pressure Switch | ||
| Compressor Reliability | Crankcase Heater | 65 watts | ||
|
| Condenser Capacity Control | Head Pressure Control Set at 84˚F, 185psig | ||
Blast |
| Reciever Capacity | 55.4lbs. @ 90% liquid refrigerant fill (37.5lbs. max | ||
| refrigerant charge) | ||||
|
|
| |||
|
|
|
| ||
| Flow Control | Accumulator | 500 Cubic Inch Capacity | ||
|
| ||||
|
| Oil Separator | Yes | ||
T40: |
| Oil Filter |
| Yes | |
Optional Outdoor Hood | Delfield | Model Number: CUHOOD |
| ||
|
| ||||
| Shipping Weight | Condensing Unit | 600 Lbs. | ||
| Outdoor Hood | 100 Lbs. | |||
|
|
27.00