6. appliance functions

6.1DATE AND TIME SETTINGS : PUSH-BUTTON (5)

Set the machine to ON .

 

Press and hold down push-button 5

for more

than five seconds to access the date and time setting

function. Display 16

οC indicates in sequence

the abbreviations Hr (hours), Mn (minutes), dA (day), Mo (month) and Yr (year), while display

15

shows their respective settings. To scroll

the abbreviations, press push-button 5

.

To modify the settings, use push-buttons

 

7

and 8

.

 

6.2ICE CREAM SURFACE HARDENING PUSH-BUTTON (6)

Set the machine to ON .

Press and hold down push-button 6 for more than five seconds to access the surface hardening function (push-button LED flashes). The compressor

is switched on; display 15 shows the default cycle time. Set the cycle time (in minutes) by means

of push-buttons 7 and 8 . Open the cell door, place the product inside, then shut the door to start the cycle. All LEDs remain off, with the exception of the Start LED. When the cycle time has elapsed, an acoustic signal is given. The appliance remains on, ready for another ice cream hardening cycle. Open the cell door, remove the hardened product, replace it, then shut the door. The machine will perform another hardening cycle for the time set for the previous one. Every time the door is opened and closed after a cycle, the time is reset. To exit the function, press push-button 6

ADDITIONAL FUNCTIONS

6.3MUTING THE BEEPER AND ALARM RESET : PUSH-BUTTON (8)

Press push-button 8 to mute the alarm beeper.

Alarms are reset :

by pressing push-button 8 when the beeper is off;

automatically if alarm conditions are removed; see also section 7 (Alarm Management).

6.4 PROGRAM STORAGE:

PUSH-BUTTON (9)

The programming function is used for cycles for processing products with the same characteristics. Up to 99 programs can be stored. Select the type of chilling process (Soft, Hard, Timed Freezing or by Temperature), then press and hold push-button 9

PROGRAM until display 16

οC shows the abbreviation

P1 (push-button 9 PROGRAM LED flashes).

Use push-buttons 7

and 8

 

to set the number

of the program on display 16

 

οC . Start up the

cycle by pressing push-button 6

. When the cycle

has been completed, the appliance automatically

switches to the set storage temperature for an

indefinite time.

 

 

 

 

Press push-button 6

to set the appliance to STOP

status (relative LED switches off), ready for a new

cycle.

 

 

 

 

RECALLING A STORED PROGRAM

When the appliance is ON

, press push-button

9 PROGRAM briefly; display 16

οC

will show program

P1. Use push-buttons 7

and 8

to select the

required program. Start up the cycle by pressing

push-button 6

.

 

 

 

Image 16
Contents T5, T14D, T20C, T24C, T40 Blast Chiller/Shock Freezers Contents General Documentation InstallationAdvice to Ensure Efficient Appliance Operation Description of the Control PanelMaintenance and Cleaning Alarm ManagementAppliance Functions General Documentation Installation AvoidCondensate drainage connection Safety and control systemsAppliance disposal Shut-down procedures Operating tipsPre-cooling Loading the applianceDescription of the Vertical Control Panel PUSH-BUTTONS Programming and operating instructions Soft Blast Chilling by Temperature pre-cooked, hot foods Bottom right of display FlashesSoft Timed Blast Chilling Hard Blast ChillingHard Blast Chilling by Temperature Hard Timed Blast ChillingBlast Freezing by Temperature Timed Blast Freezing LED 5BAppliance functions Additional FunctionsProgram Storage PUSH-BUTTON Recalling a Stored ProgramExample Printing OUT Stored Data PUSH-BUTTONForced Ventilation Function Manual DefrostingAlarm Management Display/Led Blackout alarm ALL Compressor preventive maintenance alarm ALLTemperature not reached in set time alarm ALL Keyboard/membrane alarm ALLList of other operating faults not indicated Information on AlarmsFault Cause Solution Maintenance and cleaning T5 Blast T14D Blast Chiller/Shock Freezer Blast Chiller/Shock Freezer Blast Chiller/Shock Freezer T40 Blast Chiller/Shock Freezer Btuh @ -32˚F, 90 amb, 104.4 Cond 27,500BTUH T20-24CUW Remote Water Cooled Condensing Unit Unit T40CUW Remote Water Cooled Condensing Unit T5/T14D refrigeration system schematic Wiring diagrams Page Page Page Page T40 Installation and Assembly T40 Installation and Assembly Hole for Probes Electrical Hole Refrigerant Line Holes T40 Installation and Assembly Page Page Thank you for choosing Delfield