Delfield T14D, T20C, T5, T24C manual T40 Installation and Assembly

Page 39

T40 Installation and Assembly

1.Position cabinet floor on a flat, level surface with the slotted end facing up.

NOTE: Do not break alignment block when placing panels in place.

The first panel will be the left side of the unit if you are facing the door.

NOTE: Ensure all cam locks are in the open position before placing any panels.

Make sure the skirt on the vertical panels covers the outside of the mounting floor.

Lock bottom locking cams on the outside of the first panel. Insert T-handle wrench and twist clockwise until a positive stop is achieved.

The panel will now stand on its own.

NOTE: Do not lean or push on unsupported panels.

Ensure the entryway is facing forward (gray plastic transition piece)

Insert one alignment block into the channel in between each of the locking cams.

2.Raise the first panel (with the evaporator, fans and air channel) onto the mounting floor with the fans facing inside.

• Place bottom of the panel into the alignment channel on the mounting floor for proper placement, using the alignment block to align panel.

3.Attach the back panel to the mounting floor in the same manner as the first panel. The back panel will wrap around both sides.

NOTE: Ensure all cam locks are in the open position before placing any panels.

NOTE: Do not break alignment block when placing panels in place.

Lock the side locking cams on the outside of the first panel and the left side and bottom locking cams on the inside of the back panel. Insert T-handle wrench and twist clockwise until a positive stop is achieved.

Attach deflector shields either side of the first panel as shown. The deflector shields will cover the corners on the first panel and are attached with provided screws.

Image 39
Contents T5, T14D, T20C, T24C, T40 Blast Chiller/Shock Freezers Description of the Control Panel Contents General DocumentationInstallation Advice to Ensure Efficient Appliance OperationAlarm Management Maintenance and CleaningAppliance Functions General Documentation Avoid InstallationSafety and control systems Condensate drainage connectionAppliance disposal Loading the appliance Shut-down proceduresOperating tips Pre-coolingDescription of the Vertical Control Panel PUSH-BUTTONS Programming and operating instructions Bottom right of display Flashes Soft Blast Chilling by Temperature pre-cooked, hot foodsHard Blast Chilling Soft Timed Blast ChillingHard Timed Blast Chilling Hard Blast Chilling by TemperatureBlast Freezing by Temperature LED 5B Timed Blast FreezingRecalling a Stored Program Appliance functionsAdditional Functions Program Storage PUSH-BUTTONManual Defrosting ExamplePrinting OUT Stored Data PUSH-BUTTON Forced Ventilation FunctionAlarm Management Display/Led Keyboard/membrane alarm ALL Blackout alarm ALLCompressor preventive maintenance alarm ALL Temperature not reached in set time alarm ALLInformation on Alarms List of other operating faults not indicatedFault Cause Solution Maintenance and cleaning T5 Blast T14D Blast Chiller/Shock Freezer Blast Chiller/Shock Freezer Blast Chiller/Shock Freezer T40 Blast Chiller/Shock Freezer Btuh @ -32˚F, 90 amb, 104.4 Cond 27,500BTUH T20-24CUW Remote Water Cooled Condensing Unit Unit T40CUW Remote Water Cooled Condensing Unit T5/T14D refrigeration system schematic Wiring diagrams Page Page Page Page T40 Installation and Assembly T40 Installation and Assembly Hole for Probes Electrical Hole Refrigerant Line Holes T40 Installation and Assembly Page Page Thank you for choosing Delfield