Delfield T24C, T20C, T40, T5, T14D manual Alarm Management

Page 18

7. Alarm Management

7.1 Storage of data/errors

The appliance electronic controller is equipped with a system of acoustic and visual signals to indicate the intervention of safety devices. The table below gives a list of the alarms shown on the panel display

7.2The software controls the following alarms: Evaporator probe alarm (ALL 01)

Cause:

Beeper:

Display:

Reset:

Exit from operating range (-58°F / -50°C - 212°F / +100°C) for over 30 seconds. Probe is defective (REPLACE PROBE).

Activated (3 seconds, then a pause of 30 seconds) until the mute button is pressed.

Alternates message “ALL 01” with standard display

Automatically resets only when probe reading has returned to normal.

Core probe alarm (ALL 02)

Cause:

Exit from operating range (-58°F / -50°C - 212°F / +100°C) for more than 30 seconds during

 

current chilling cycle by temperature.

Effect:

Interruption of current chilling cycle by temperature and automatic start-up of timed

 

chilling cycle. Chilling by temperature push-button disabled.

 

Probe is defective (REPLACE PROBE).

Beeper:

Activated (3 seconds, then a pause of 30 seconds) until the mute button is pressed.

Display:

Alternates message “ALL 02” with standard display

Alarm relay:

Not activated.

Reset:

Press the mute push-button (with beeper off).

 

Resets automatically if probe value returns to normal, but cycle remains in timed mode.

 

Alternatively, switch off the panel then turn it back on (stand-by).

 

 

 

Compartment probe alarm (ALL 03)

 

 

Cause:

Exit from operating range (-58°F / -50°C - 212°F / +100°C) for over 30 seconds.

 

Probe is defective (REPLACE PROBE).

Effect:

Any current chilling cycle is interrupted.

 

If a storage phase is in progress, the compressor and the fan set to stand-by status.

 

When the appliance is in Stop status, press Start to set the compressor and fan to stand by.

Beeper:

Activated (3 seconds, then a pause of 30 seconds) until the mute button is pressed.

Display:

Alternates message “ALL 03” with standard display

Reset:

Automatically resets only when probe reading has returned to normal.

 

 

Image 18
Contents T5, T14D, T20C, T24C, T40 Blast Chiller/Shock Freezers Advice to Ensure Efficient Appliance Operation Contents General DocumentationInstallation Description of the Control PanelAlarm Management Maintenance and CleaningAppliance Functions General Documentation Installation AvoidSafety and control systems Condensate drainage connectionAppliance disposal Pre-cooling Shut-down proceduresOperating tips Loading the applianceDescription of the Vertical Control Panel PUSH-BUTTONS Programming and operating instructions Soft Blast Chilling by Temperature pre-cooked, hot foods Bottom right of display FlashesSoft Timed Blast Chilling Hard Blast ChillingHard Blast Chilling by Temperature Hard Timed Blast ChillingBlast Freezing by Temperature Timed Blast Freezing LED 5BProgram Storage PUSH-BUTTON Appliance functionsAdditional Functions Recalling a Stored ProgramForced Ventilation Function ExamplePrinting OUT Stored Data PUSH-BUTTON Manual DefrostingAlarm Management Display/Led Temperature not reached in set time alarm ALL Blackout alarm ALLCompressor preventive maintenance alarm ALL Keyboard/membrane alarm ALLInformation on Alarms List of other operating faults not indicatedFault Cause Solution Maintenance and cleaning T5 Blast T14D Blast Chiller/Shock Freezer Blast Chiller/Shock Freezer Blast Chiller/Shock Freezer T40 Blast Chiller/Shock Freezer Btuh @ -32˚F, 90 amb, 104.4 Cond 27,500BTUH T20-24CUW Remote Water Cooled Condensing Unit Unit T40CUW Remote Water Cooled Condensing Unit T5/T14D refrigeration system schematic Wiring diagrams Page Page Page Page T40 Installation and Assembly T40 Installation and Assembly Hole for Probes Electrical Hole Refrigerant Line Holes T40 Installation and Assembly Page Page Thank you for choosing Delfield