Creda Single Oven manual Electrical Connection, Connect to a 230-240V A.C. Supply only

Page 31

ELECTRICAL CONNECTION

WARNING – THIS APPLIANCE MUST BE EARTHED.

CONNECT TO A 230-240V A.C. SUPPLY ONLY.

Connection to the electricity supply should be made via a properly earthed, readily accessible wall socket which is adjacent to, and not more than 1.25m away from the appliance and capable of electrical isolation.

The mains lead should be routed such that it cannot touch hot parts of the appliance i.e. the back panel above a height of 350mm from the bottom of the oven recess. If the oven is to be wired into a connector unit, this may be positioned behind the oven providing the following requirements are met:

i)The connector unit must not project more than 25mm from the wall.

ii)The top of the connector unit must not be more than 350mm above the base of the oven recess.

NOTE: The removed plug cannot be used for any other appliance and should therefore be properly disposed of and not left where children might find it and plug it into a supply socket – with the obvious consequent danger.

IF THE FITTED PLUG IS REMOVED

The flexible mains lead must be correctly connected as below to a three pin plug of not less than 13 amp capacity. If a B.S. 1363 fused plug is used, it must be fitted with a 3 amp fuse which is approved to B.S. 1362.

IMPORTANT: The wires in the mains lead fitted to this appliance are coloured in accordance with the following code:

GREEN AND YELLOW

– EARTH

 

 

BLUE

– NEUTRAL

 

Blue to

 

BROWN

– LIVE

Neutral

 

 

 

Cord Clamp

Green &

Yellow to

Earth

Brown to Live

3 Amp

Fuse

As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:– The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured green or green and yellow. The wire which is coloured blue must be connected to the terminal which is marked with the N or coloured black. The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. When wiring the plug, ensure that all strands of wire are securely retained in each terminal. Do not forget to tighten the mains lead clamp on the plug. As the appliance must be earthed, do not use 2-pin sockets outlets, if you are in doubt, consult a qualified electrician.

Should the mains lead ever require replacement, it is essential that this operation be carried out by a qualified electrician and should only be replaced with a flexible cord of the same size i.e. 0.75mm2 cross sectional area and temperature rating of 85˚ C e.g. heat resisting PVC.

IF A MOULDED PLUG IS FITTED

In the event of replacing a fuse in the plug supplied a 3 amp ASTA approved fuse to BS1362 must be fitted.

NOTE: The fuse cover must be refitted when changing the fuse. In the event of losing the

fuse cover the plug must not be used until a replacement fuse cover has been obtained and fitted. A new fuse cover can be obtained from your local electrical retailer. The colour of the correct replace- ment fuse cover is that of the coloured marks or inserts in the base of the plug.

31

Image 31
Contents Single Ovens Users Instruction & Installation Book Creda Answer Centre 0541 54 64 Contents Introduction Always For Your SafetyNever Features Control Markings ControlsAutomatic Cooking Oven Timer OperationHints on Automatic Cooking Clockface Know Your TimerSymbols Timer Function ButtonsSetting the Minute Minder Setting the Time of DAYAuto Cooking Programmes Appropriate oven function Other Notes on Timer Operation ABC Grill PAN & HandleYoung Children should be Kept Away Using the GrillMain Oven Operation Using the OvenShelf Positioning Main Oven UtensilsCold Start Cooking Using the ‘SLOW COOK’ Setting Shelf position 1 is the highest Main Oven Cooking ChartYeast Mixtures Credaclean Oven Liners Care and CleaningCleaning Main Oven and Grill HOW to Clean the Lamp Lens Replacement of the Oven LampControl Panel / Trims / Inner Door Panel & Glass Cleaning the Doors Location Installation InstructionsGAS Safety Installation & USE Regulations Model Numbers CB01GGeneral Technical DataList of Loose Items InstallationFinal Installation Ventilation560mm 565mm Deep Connecting to GAS SupplyConnect to a 230-240V A.C. Supply only Electrical ConnectionInstallation and Operational Checks Something WRONG? Problem CheckPage Page Key Contacts