4-12. Back up Function (Basic Model)
INPUT | CONTROL OBJECT |
None | 1. |
|
|
CONTENTS | REMARKS |
|
|
1.Filter Exchange Information : Record as a
2.P Factor (Information about Ice Maker)
4-13. Automatic Icemaker ( Dispenser Model)
|
| INPUT |
|
| CONTROL OBJECT |
|
| Full ice sensing switch |
|
|
|
|
| Ice Maker Lock |
|
| Ice separating motor |
|
| Sensors |
|
|
|
|
|
|
|
|
|
|
|
| CONTENTS | REMARKS | |
1. Flow of ice making |
|
|
| ||
|
|
|
|
|
|
|
| START |
|
|
|
|
|
|
|
| |
|
| Ice making mode | ▶ Ice is being made |
| |
|
|
|
|
| |
|
| (water supply stand by) |
| ||
|
|
|
|
| |
|
| Ice separating mode | ▶ Ice tray is twisted to separate |
| |
|
|
| ice cubes |
| |
|
|
|
| ||
|
|
|
|
| |
|
| Water supply mode | ▶ Water is supplied to ice tray |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Water supply | ▶ Check is water is supplied OK. |
| |
|
| check mode |
| ||
|
| RETURN |
|
|
|
|
|
|
|
|
|
1)Press TEST switch under the Icemaker for more than 1 second and test starts.
*Test mode starts from ice separating mode.
*In case test switch has an error of short, test is done only once.