TOA Electronics SSDV-3328 installation instructions Top View, Front View, Right Side View

Page 11

fireplace specifications

Notes

 

FRAMING WITH SQUARE HORIZONTAL TERMINATION (SV4.5HT-2)

 

 

 

 

Due to Lennox' ongoing commitment to quality,

VENT FRAMING -

 

Framing should be constructed

all specifications, ratings and dimensions are

 

TOP VENT WITH ONE

10-1/2

of 2 x 4 or larger lumber.

subject to change without notice.

90¡ ELBOW

 

 

(267)

 

 

 

 

 

Vent Size

 

VENT FRAMING -

 

 

 

REAR VENT WITH

 

 

 

4-1/2" Inner

NO ELBOWS

 

 

Co-axial DV Vent Size

 

 

7

7-1/2" Outer

 

 

 

 

 

(178)

 

 

 

5-1/8

 

 

 

12-1/8

 

 

 

(130)

 

 

 

 

(308)

Vertical Venting Through the Ceiling: Frame ceiling opening - Use a plumb line from the ceiling above the appli- ance to locate center of the vertical run. Cut and/or frame an opening, 10-1/2" x 10-1/2" (267 mm x 267 mm) inside dimensions, about this center mark (see Figure 19).

FRAMING

21-1/2

SPACERS

(546)

(Top and Sides

10-3/4

and Rear)

(273)

 

 

 

7

 

37-1/8

5-1/8

(178)

 

12-1/8

33-1/4

(943)

(130)

(845)

 

 

(308)

19-5/8

(498)

*12-7/8

16-5/8

(327)

 

(422)

 

33-1/4

*12-7/8 inches (327 mm) is the

(845)

required framing depth dimension

 

when the finish material (drywall)

Inches (mm)

thickness is 1/2 in. (13mm).

*CONCENTRIC FLUE

FLUE - 4-1/2 (114) COMBUSTION AIR - 7-1/2

*SSDVR models have only a rear vent *SSDVT models have only a top vent

Top View

33-1/8

(841)

1

(25)

17

33-1/827-1/2(432)

(841)

(699)

Front View

Figure 14

6-13/16

(173)Inches (millimeters)

 

 

13

 

 

 

NOTE - Eyebrow

(330)

 

 

3 (76)

 

 

 

hood shown as positioned

 

1/2 (13)

 

 

in louvered front model.

 

 

 

ELECTRICAL INLET

 

 

 

 

2-3/4 x 2 (70 x 51)

 

 

 

 

COVER PLATE with

 

 

 

 

KNOCKOUT)

 

 

 

30-1/8

 

 

1 (25)

 

(765)

GAS INLET

8-11/32

 

**19-5/8

 

(Either Side

(212)

1-5/8

 

(498)

 

and bottom)

 

 

3 (76)

 

(42)

 

 

 

 

 

 

 

 

2-3/4**Rear vent models only

 

 

Right Side View

(70)

 

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

11

Image 11
Contents OTL Report No -F-29-5 700,043M REV. a 06/2008Table of Contents Natural and Propane Gas Model Series ModelsSSDVT/R-3328 Electronic ModelsSIT Millivolt MassachusettsMassachusetts Horizontal Vent Re- quirements New York City, New YorkLocation Cold Climate InsulationManufactured Home Requirements Roof Pitch Feet Vent Termination ClearancesHorizontal Vent Termination Clearances Vertical Vent Termination ClearancesInches 30cm Canadian Installation US InstallationMeter/regulator assembly = Clearance to service regulator vent outlet Feet 91cmSpacers Minimum Clearances to CombustiblesWall Finishes / Surrounds / Mantels Appliance and Vent ClearancesRouting Gas Line Detailed Installation StepsTypical Installation Sequence FramingRight Side View Top ViewFront View Length feet Fireplace Framing specificationsProper Sizing of Gas Line Schedule 40 / Black Iron PipeSelect Venting System Horizontal or Vertical Install the Vent System General InformationInstallation of Vent Restrictor These fireplaces must be vented directly to the outsideEffective Vent Length Vertical Straight InstallationVertical Termination Systems Roof Attach vent components to each other Vertical Offset Installation267 mm 451 mm PitchIf the vent system extends more than 5 feet 10-1/2 267 mm 305 mm524 Elbow Only 305 048 610 572 914 096 219 Vertical Vent FIGURES/TABLES610 305 219 829 914 438 Table B Maximum Minimum Feet MeterTable D + H1 Maximum Minimum Table CMaximum Minimum Feet Meter Meter 524 610 305 048 219 572 829 914 096 438See on Page 14 or on See on Page 11 for Min Install Firestop/Spacer at exterior wallInstall the Square Termination SV4.5HT-2 or SF4.5HT-2 Horizontal Vent FIGURES/TABLES Horizontal Vent Figures / Tables Square termination SV4.5HT-2 shown Attach Flex Vent to Termination Install the Outer Flex PipePull and extend outer flexible vent pipe Flexible Vent SectionSee Figure Field WiringWiring Optional Forced Air Blower Kit SIT and Honeywell Millivolt WiringSchematic Representation Only Connecting Gas LineSIT Gas Valve Reinstalling Control Compartment DoorChecking Appliance Opera- tion SIT and Honeywell Millivolt Appliance CheckoutGlowing Embers Install Logs, Volcanic StoneElectronic Appliance Checkout Glowing Embers Firebox Accessories / PartsAir Shutter Adjustment Guidelines Installing the Glass DoorInstalling Glass Enclosure Panels Burner Adjustments Flame Appearance and sootingRefer to Figure Burner Air Shutter Adjustment ProcedureHood Installation Finishing Requirements Wall DetailsCat. No Model Description Closed Top Shroud Termination Kits Cat. NoAll compressed flex vents can be expanded up to two times Listed Secure Flex ComponentsModel Description Listed Secure Vent ComponentsPilot for SIT Millivolt Gas Valve Adjusting KnobMillivolt Appliances SIT Systems SIT Millivolt Gas ValveFlare Nut Clip Ignitor Assembly

SSDV-3328 specifications

TOA Electronics SSDV-3328 is an advanced digital mixing amplifier designed to provide high-quality sound reinforcement for various applications, including commercial facilities, educational institutions, and public address systems. This versatile amplifier combines several key features and cutting-edge technologies to deliver exceptional audio performance and flexibility.

One of the standout characteristics of the SSDV-3328 is its robust power output. With a rating of 150 watts per channel, it is capable of driving a variety of speaker setups, ensuring that sound coverage is both powerful and consistent across large areas. This makes it an ideal choice for venues such as auditoriums, conference rooms, and exhibition halls.

The SSDV-3328 offers a unique blend of analog and digital input options, allowing seamless integration with various audio sources. It supports connectivity through balanced XLR inputs, RCA, and even digital input formats, providing users with the capabilities needed to connect microphones, musical instruments, and playback devices. This flexibility is invaluable for professionals who require adaptable solutions for different audio setups.

Equipped with TOA's advanced DSP (Digital Signal Processing) technology, the amplifier provides enhanced audio quality and control. Users can benefit from features such as graphic equalization, delay settings, and limiting, which enable precise tuning of the audio output to match the acoustics of any space. This capability ensures that the audio remains clear and intelligible, regardless of the complexity of the setup.

Another noteworthy feature of the SSDV-3328 is its built-in feedback suppression technology, designed to minimize feedback issues that can occur in live sound situations. This not only enhances the listening experience but also reduces the workload on sound technicians during events.

The design of the SSDV-3328 emphasizes reliability and ease of use. Its intuitive control panel includes well-organized knobs and switches for quick adjustments, while status indicators provide real-time feedback on system performance. Additionally, the lightweight and compact construction of the amplifier makes it easy to transport and install, meeting the demands of both permanent installations and portable setups.

In summary, TOA Electronics SSDV-3328 stands out in the realm of digital mixing amplifiers, offering powerful output, versatile connectivity, advanced DSP features, and a commitment to audio quality. Whether used in commercial spaces or live events, this amplifier is designed to deliver performance that meets the highest standards in sound reinforcement. Its thoughtful design and innovative technologies make it a reliable choice for audio professionals seeking a top-tier mixing amplifier.