TOA Electronics SSDV-3328 Install Firestop/Spacer at exterior wall, See on Page 11 for Min

Page 20

20

J. Assemble vent run to exterior wall - If not previously measured, locate the center of the vent at the exterior wall. Prepare an opening as described in Step B. Assemble the vent system to point where the terminus of the last section is located relative to the exterior surface to which the termination is to be attached (see Figures 32 & 33 and Table 12 on Page 21.

If the terminus of the last section is not within this distance, use the telescopic vent section SV4.5LA, as the last vent section. For wall thick- nesses greater than that shown in Figure 33 on Page 20 and Table 12 on Page 21. This table lists the additional venting components needed (in addition to the termination and adapter) for a particular range of wall thicknesses.

K. Attach termination adapter - Attach the adapter (adapter - SV4.5RCH - provided with the termination) to the vent section or telescoping vent section, elbow or appliance collar as shown in Figures 32 & 33 in the same manner as any SV4.5 vent component (refer to Step E).

L. Install Firestop/Spacer at exterior wall

-When using the square termination, install SV4.5HF (Secure Vent), SF4.5HF (Secure Flex) Firestop/Spacer over the opening at the exterior side of the framing, long side up, with the 3 inch spacer clearance at the top as shown in Figure 32, and nail into place.

(The Firestop/Spacer may also be installed over the opening at the interior side of framing).

M. Install the Square Termination (SV4.5HT-2 or SF4.5HT-2)

Install the square termination - For the last step

,from outside the exterior wall, slide the collars of the termination onto the adapter (the outer inside the outer and the inner outside the inner) until the termination seats against the exterior wall surface to which it will be attached. Orient the housing of the termination with the arrow pointed upwards. Secure the termination to the exterior wall. The horizontal termination must not be recessed into the exterior wall or siding by more than the 1-1/4" (32 mm) as shown in Figure 33.

IMPORTANT

The vent termination is hot while in operation and for a period of time following the use of the fire- place. To prevent contact with hot surfaces, we recommend the use of a Termination Guard. See Items 12 and 13 on Page 32. This can be purchased at your local dealer.

 

 

To help minimize water infiltration it is

 

 

recommended that the Firestop/Spacer

 

 

(SV4.5HF) be installed on the exterior

 

 

side of the wall.

 

 

SV4.5 HT-2

 

7"

Termination

12¹⁄"

(178)

10¹⁄"

 

(308 mm)

 

(267mm)

 

5¹⁄"

 

(130 mm)

3"

 

 

 

 

(76 mm)

Adapter

 

1"

 

(25.4 mm)

SV4.5RCH

 

 

 

 

Note: Centerline of Vent Piping is

 

 

NOT the Same as the Centerline of

 

 

the Framed Opening.

6 to 48 inch Vent Section,

See Figure 14 on Page 11 for Min.

Distance to Base of Appliance.

Telescopic vent section,

 

Elbow or Appliance Collar

Base of Appliance

 

 

Figure 32 - INSTALLING SQUARE HORIZONTAL TERMINATION (SV4.5HT-2 or SF4.5HT-2)

Use silicone caulking to seal

 

Maximum Wall Thickness

the top and sides of the

 

 

 

10 in. (254 mm)

termination, up to the

 

Interior Surface of

Exterior Surface of Siding

underlayment, stucco, or

masonry wall surface.

 

Finished Wall

Exterior Surface of

 

 

Maximum Extent of

Framing

Siding

 

6 in. to 9-1/4 in.

 

Vent Run Sections

Caulk

 

 

Relative to Exterior

(152 to 235 mm)

 

 

Surface of Framing

 

 

 

Last Vent Section.

 

 

 

Use Telescopic Vent

 

 

 

Section (SV4.5LA), If

 

 

 

Necessary

 

SV4.5 HT-2

 

 

 

 

Termination

Caulk

 

SV4.5 HT-2

 

 

 

 

 

 

 

 

Termination

Adapter

 

 

 

 

 

 

 

 

SV4.5RCH

1-1/4” Maximum Recess of

 

 

 

 

 

 

 

 

Square Termination

Stucco

 

vFor thicknesses greater

into Exterior Finishing Material

 

 

 

 

than 10", see Table 12

 

Figure 33

Venting Connection and Exterior Wall Recessing of the Horizontal Square

Termination (SV4.5HT-2 or SF4.5HT-2).

 

Horizontal terminations have been designed to perform in a wide range of weather conditions. Our terminations meet or exceed industry standards.

When selecting the locations of your horizontal terminations, do not place the termination where water from eaves and adjoining rooflines may create a heavy flow of cascading water onto the termination cap. If the cap must be placed where the possibility of cascading water exists, it is the responsibility of the builder to direct the water away from the termination cap by using gutters or other means.

Take care to carefully follow the installation instructions for the termination, including the use of silicone caulking where required.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Image 20
Contents 700,043M REV. a 06/2008 OTL Report No -F-29-5Table of Contents Models SSDVT/R-3328Electronic Models Natural and Propane Gas Model SeriesMassachusetts Massachusetts Horizontal Vent Re- quirementsNew York City, New York SIT MillivoltCold Climate Insulation LocationManufactured Home Requirements Vent Termination Clearances Horizontal Vent Termination ClearancesVertical Vent Termination Clearances Roof Pitch FeetCanadian Installation US Installation Meter/regulator assembly= Clearance to service regulator vent outlet Feet 91cm Inches 30cmMinimum Clearances to Combustibles Wall Finishes / Surrounds / MantelsAppliance and Vent Clearances SpacersDetailed Installation Steps Typical Installation SequenceFraming Routing Gas LineRight Side View Top ViewFront View Fireplace Framing specifications Proper Sizing of Gas LineSchedule 40 / Black Iron Pipe Length feetInstall the Vent System General Information Installation of Vent RestrictorThese fireplaces must be vented directly to the outside Select Venting System Horizontal or VerticalEffective Vent Length Vertical Straight InstallationVertical Termination Systems Roof Vertical Offset Installation Attach vent components to each otherPitch If the vent system extends more than 5 feet10-1/2 267 mm 305 mm 267 mm 451 mmVertical Vent FIGURES/TABLES 610 305 219 829 914 438Table B Maximum Minimum Feet Meter 524 Elbow Only 305 048 610 572 914 096 219Table C Maximum Minimum Feet MeterMeter 524 610 305 048 219 572 829 914 096 438 Table D + H1 Maximum MinimumSee on Page 14 or on See on Page 11 for Min Install Firestop/Spacer at exterior wallInstall the Square Termination SV4.5HT-2 or SF4.5HT-2 Horizontal Vent FIGURES/TABLES Horizontal Vent Figures / Tables Square termination SV4.5HT-2 shown Install the Outer Flex Pipe Pull and extend outer flexible vent pipeFlexible Vent Section Attach Flex Vent to TerminationField Wiring Wiring Optional Forced Air Blower KitSIT and Honeywell Millivolt Wiring See FigureConnecting Gas Line Schematic Representation OnlyReinstalling Control Compartment Door Checking Appliance Opera- tionSIT and Honeywell Millivolt Appliance Checkout SIT Gas ValveGlowing Embers Install Logs, Volcanic StoneElectronic Appliance Checkout Firebox Accessories / Parts Glowing EmbersInstalling the Glass Door Installing Glass Enclosure PanelsBurner Adjustments Flame Appearance and sooting Air Shutter Adjustment GuidelinesBurner Air Shutter Adjustment Procedure Hood InstallationFinishing Requirements Wall Details Refer to FigureCat. No Model Description Cat. No Closed Top Shroud Termination KitsListed Secure Flex Components Model DescriptionListed Secure Vent Components All compressed flex vents can be expanded up to two timesAdjusting Knob Millivolt Appliances SIT SystemsSIT Millivolt Gas Valve Pilot for SIT Millivolt Gas ValveIgnitor Assembly Flare Nut Clip

SSDV-3328 specifications

TOA Electronics SSDV-3328 is an advanced digital mixing amplifier designed to provide high-quality sound reinforcement for various applications, including commercial facilities, educational institutions, and public address systems. This versatile amplifier combines several key features and cutting-edge technologies to deliver exceptional audio performance and flexibility.

One of the standout characteristics of the SSDV-3328 is its robust power output. With a rating of 150 watts per channel, it is capable of driving a variety of speaker setups, ensuring that sound coverage is both powerful and consistent across large areas. This makes it an ideal choice for venues such as auditoriums, conference rooms, and exhibition halls.

The SSDV-3328 offers a unique blend of analog and digital input options, allowing seamless integration with various audio sources. It supports connectivity through balanced XLR inputs, RCA, and even digital input formats, providing users with the capabilities needed to connect microphones, musical instruments, and playback devices. This flexibility is invaluable for professionals who require adaptable solutions for different audio setups.

Equipped with TOA's advanced DSP (Digital Signal Processing) technology, the amplifier provides enhanced audio quality and control. Users can benefit from features such as graphic equalization, delay settings, and limiting, which enable precise tuning of the audio output to match the acoustics of any space. This capability ensures that the audio remains clear and intelligible, regardless of the complexity of the setup.

Another noteworthy feature of the SSDV-3328 is its built-in feedback suppression technology, designed to minimize feedback issues that can occur in live sound situations. This not only enhances the listening experience but also reduces the workload on sound technicians during events.

The design of the SSDV-3328 emphasizes reliability and ease of use. Its intuitive control panel includes well-organized knobs and switches for quick adjustments, while status indicators provide real-time feedback on system performance. Additionally, the lightweight and compact construction of the amplifier makes it easy to transport and install, meeting the demands of both permanent installations and portable setups.

In summary, TOA Electronics SSDV-3328 stands out in the realm of digital mixing amplifiers, offering powerful output, versatile connectivity, advanced DSP features, and a commitment to audio quality. Whether used in commercial spaces or live events, this amplifier is designed to deliver performance that meets the highest standards in sound reinforcement. Its thoughtful design and innovative technologies make it a reliable choice for audio professionals seeking a top-tier mixing amplifier.