TOA Electronics SSDV-3328 installation instructions Square termination SV4.5HT-2 shown

Page 23

HORIZONTAL VENT FIGURES / TABLES (CONTINUED)

Wall Firestop/Spacer

(SV4.5HF)

H1

H2

 

 

Table K

 

 

 

 

 

 

 

 

H + H1 + H2 Maximum

H Maximum

V Minimum

feet

(meter)

feet

(meter)

feet

(meter)

 

 

 

 

 

 

5

(1.524)

2

(0.610)

1

(0.305)

 

 

 

 

 

 

10

(3.048)

4

(1.219)

2

(0.610)

15

(4.572)

6

(1.829)

3

(0.914)

 

 

 

 

 

 

20

(6.096)

8

(2.438)

4

(1.219)

 

 

 

 

 

 

 

V + H + H

+ H = 40 feet (12.2 m) Max

 

Square termination (SV4.5HT-2) shown.

When using Secure Flex, use Firestop/Spacer SF4.5VF.

When using Secure Flex, use Firestop/Spacer SF4.5HF.

V

Ceiling

Firestop/Spacer

(SV4.5VF)

 

1

2

 

H = 8 feet (2.438 meters) Max.

 

H + H1+ H2 = 20 feet (6.096 meters) Max.

 

Example: If 20 feet total (H+H1+H2) horizontal vent

 

run is needed, then 4 feet minimum of (V) vertical

 

vent will be required.

 

This table shows a 1(V) to 5(H) ratio. For every

 

1 foot of (V) vertical, you are allowed 5 feet of

 

horizontal run up to a maximum total (H+H1+H2)

 

horizontal run of 20 feet.

 

See Table 12 on Page 21 as an aid in venting

H

component selection for a particular range of

 

exterior wall thicknesses.

Figure 39 - Rear Vent - THREE 90 DEGREE ELBOWS

 

 

 

 

Table L

 

 

When using Secure Flex,

 

H + H1 Maximum

V Minimum

 

use Firestop/Spacer

 

feet

(meter)

feet

(meter)

 

SF4.5VF.

 

 

 

5

(1.524)

Elbow Only

H1

When using Secure

 

Flex, use Firestop/Spacer

 

5

(1.524)

1

(0.305)

 

SF4.5HF.

 

 

 

 

 

 

 

 

Ceiling

 

10

(3.048)

2

(0.610)

 

 

15

(4.572)

3

(0.914)

 

Firestop/Spacer

 

 

(SV4.5VF)

 

20

(6.096)

4

(1.219)

 

 

 

 

 

 

H + H1 = 20 feet (6.096 m) Max.

Wall Firestop/Spacer

H

 

V + V1+ H + H1 = 40 ft. (12.192 m) Max.

(SV4.5HF)

V1

 

Example: If 20 feet total (H+H1) horizontal vent

 

 

 

 

V

run is needed, then 4 feet minimum of (V) vertical

 

 

vent will be required.

 

 

See Table 12 on Page

 

 

 

 

 

 

This table shows a 1(V) to 5(H) ratio. For every 1

21 as an aid in venting

 

 

 

 

foot of (V) vertical, you are allowed 5 feet of (H+

component selection for

 

 

a particular range of exte-

 

 

H1) horizontal run, up to a maximum horizontal

rior wall thicknesses.

 

 

run of 20 feet.

 

 

 

 

 

An elbow is acceptable as 1 foot of vertical rise

 

Wall Firestop/Spacer

 

except where an elbow is the only vertical com-

 

 

ponent in the system. See Figure 35.

 

(SV4.5HF)

 

 

 

 

 

 

 

 

Square termination (SV4.5HT-2) shown.

Figure 40 - Top Vent - THREE 90 DEGREE ELBOWS

 

 

 

 

 

 

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

 

 

 

 

23

Image 23
Contents OTL Report No -F-29-5 700,043M REV. a 06/2008Table of Contents Natural and Propane Gas Model Series ModelsSSDVT/R-3328 Electronic ModelsSIT Millivolt MassachusettsMassachusetts Horizontal Vent Re- quirements New York City, New YorkLocation Cold Climate InsulationManufactured Home Requirements Roof Pitch Feet Vent Termination ClearancesHorizontal Vent Termination Clearances Vertical Vent Termination ClearancesInches 30cm Canadian Installation US InstallationMeter/regulator assembly = Clearance to service regulator vent outlet Feet 91cmSpacers Minimum Clearances to CombustiblesWall Finishes / Surrounds / Mantels Appliance and Vent ClearancesRouting Gas Line Detailed Installation StepsTypical Installation Sequence FramingRight Side View Top ViewFront View Length feet Fireplace Framing specificationsProper Sizing of Gas Line Schedule 40 / Black Iron PipeSelect Venting System Horizontal or Vertical Install the Vent System General InformationInstallation of Vent Restrictor These fireplaces must be vented directly to the outsideEffective Vent Length Vertical Straight InstallationVertical Termination Systems Roof Attach vent components to each other Vertical Offset Installation267 mm 451 mm PitchIf the vent system extends more than 5 feet 10-1/2 267 mm 305 mm524 Elbow Only 305 048 610 572 914 096 219 Vertical Vent FIGURES/TABLES610 305 219 829 914 438 Table B Maximum Minimum Feet MeterTable D + H1 Maximum Minimum Table CMaximum Minimum Feet Meter Meter 524 610 305 048 219 572 829 914 096 438See on Page 14 or on See on Page 11 for Min Install Firestop/Spacer at exterior wallInstall the Square Termination SV4.5HT-2 or SF4.5HT-2 Horizontal Vent FIGURES/TABLES Horizontal Vent Figures / Tables Square termination SV4.5HT-2 shown Attach Flex Vent to Termination Install the Outer Flex PipePull and extend outer flexible vent pipe Flexible Vent SectionSee Figure Field WiringWiring Optional Forced Air Blower Kit SIT and Honeywell Millivolt WiringSchematic Representation Only Connecting Gas LineSIT Gas Valve Reinstalling Control Compartment DoorChecking Appliance Opera- tion SIT and Honeywell Millivolt Appliance CheckoutGlowing Embers Install Logs, Volcanic StoneElectronic Appliance Checkout Glowing Embers Firebox Accessories / PartsAir Shutter Adjustment Guidelines Installing the Glass DoorInstalling Glass Enclosure Panels Burner Adjustments Flame Appearance and sootingRefer to Figure Burner Air Shutter Adjustment ProcedureHood Installation Finishing Requirements Wall DetailsCat. No Model Description Closed Top Shroud Termination Kits Cat. NoAll compressed flex vents can be expanded up to two times Listed Secure Flex ComponentsModel Description Listed Secure Vent ComponentsPilot for SIT Millivolt Gas Valve Adjusting KnobMillivolt Appliances SIT Systems SIT Millivolt Gas ValveFlare Nut Clip Ignitor Assembly

SSDV-3328 specifications

TOA Electronics SSDV-3328 is an advanced digital mixing amplifier designed to provide high-quality sound reinforcement for various applications, including commercial facilities, educational institutions, and public address systems. This versatile amplifier combines several key features and cutting-edge technologies to deliver exceptional audio performance and flexibility.

One of the standout characteristics of the SSDV-3328 is its robust power output. With a rating of 150 watts per channel, it is capable of driving a variety of speaker setups, ensuring that sound coverage is both powerful and consistent across large areas. This makes it an ideal choice for venues such as auditoriums, conference rooms, and exhibition halls.

The SSDV-3328 offers a unique blend of analog and digital input options, allowing seamless integration with various audio sources. It supports connectivity through balanced XLR inputs, RCA, and even digital input formats, providing users with the capabilities needed to connect microphones, musical instruments, and playback devices. This flexibility is invaluable for professionals who require adaptable solutions for different audio setups.

Equipped with TOA's advanced DSP (Digital Signal Processing) technology, the amplifier provides enhanced audio quality and control. Users can benefit from features such as graphic equalization, delay settings, and limiting, which enable precise tuning of the audio output to match the acoustics of any space. This capability ensures that the audio remains clear and intelligible, regardless of the complexity of the setup.

Another noteworthy feature of the SSDV-3328 is its built-in feedback suppression technology, designed to minimize feedback issues that can occur in live sound situations. This not only enhances the listening experience but also reduces the workload on sound technicians during events.

The design of the SSDV-3328 emphasizes reliability and ease of use. Its intuitive control panel includes well-organized knobs and switches for quick adjustments, while status indicators provide real-time feedback on system performance. Additionally, the lightweight and compact construction of the amplifier makes it easy to transport and install, meeting the demands of both permanent installations and portable setups.

In summary, TOA Electronics SSDV-3328 stands out in the realm of digital mixing amplifiers, offering powerful output, versatile connectivity, advanced DSP features, and a commitment to audio quality. Whether used in commercial spaces or live events, this amplifier is designed to deliver performance that meets the highest standards in sound reinforcement. Its thoughtful design and innovative technologies make it a reliable choice for audio professionals seeking a top-tier mixing amplifier.