TOA Electronics SSDV-3328 Minimum Clearances to Combustibles, Wall Finishes / Surrounds / Mantels

Page 9

Minimum Clearances to Combustibles

Hearth Extension - A hearth extension is not required with this appliance. If a hearth extension is used, do not block the lower control compartment door. Any hearth extension used is for appearance only and does not have to conform to standard hearth extension installation requirements.

Wall Finishes / Surrounds / Mantels

Note: Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined by the appliance front face (black sheet metal). Never allow combustible materials to be positioned in front of or overlapping the appliance front face. See Figure 57 on Page 31.

Non-combustible materials, such as surrounds and other appliance trim, may be installed on the appliance front face with these exceptions: they must not cover any portion of the removable glass panel or louvers.

Vertical installation clearances to combustible mantels vary according to the depth of the mantel. See Figure 8. Mantels constructed of non-combustible materials may be installed at any height above the appliance opening; however, do not allow anything to hang below the hood.

Appliance and Vent Clearances

The appliance is approved with zero clearance to combustible materials on all sides (as detailed in Table 8), with the following exception: When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit. Refer to Figure 4.

MINIMUM CLEARANCES Inches (millimeters)

Back

1/2 (13)

 

0 (0) Spacers

Sides

1/2 (13)

 

0 (0) Spacers

 

 

Top Spacers

0 (0)

 

 

Floor

0 (0)

Mantel Depth

14 (356)

12(305)

10 (254)

8 (203)

6 (152)

4 (102)

12 10 8 6 4 2

(305) (254) (203) (152) (102) (51)

Hood

Figure 8 - Minimum Mantel Clearances

inches (millimeters)

Top of

Appliance

Bottom of Appliance

64 (1626)

To Ceiling

 

Vent

3 (76) Top *

 

1 (25.4) Sides & Bottom

 

 

SERVICE CLEARANCES Feet (meters)

 

 

Front

3 ft. (0.9 m)

 

 

Table 8

*Note: 3 in. (75 mm) above any horizontal/in- clined vent component.

**Note: See Page 10, Step 1 for clearance requirements to the nailing flange located at each side of the unit and any screw heads adjacent to it.

Model No.

Combustible Shelf Height - Inches (millimeters)

 

 

 

 

Top Vent - with One 90 Degree Elbow

Rear Vent - Straight Out the Back

 

 

Secure Vent

Secure Flex

Secure Vent

Secure Flex

 

 

(flex elbow)

 

 

 

 

 

 

 

SSDVT-3328

*44-1/8(1121)

*45-7/8 (1165)

N/A

N/A

 

 

 

 

 

SSDVR-3328

N/A

N/A

33 1/4 (845)

33 1/4 (845)

* Includes 3” clearance to combustibles (required above vent components)

Minimum Distance to Unprotected Side Wall

Combustible materials may project beyond the sides of the fire- place opening as long as they are kept within the shaded areas illustrated here.

At 14" minimum

At 8-1/4" side

 

side wall clearance,

 

a combustible wall

wall clearance, a

Top View of

can project to any

combustible wall

Fireplace

length.

can project 12"

 

Do not insulate the space between the appliance and the area above it.

Shelf Height

(see table)

Do not insulate the

space between the

appliance and the

area above it.

*Shelf Height

(see table)

45o

Combustible Materials

Allowed In Shaded

5 (127)

Area “Safe Zone”

 

Combustible Walls

 

shown in dark gray

12 (305)

 

19 (483)

Inches (millimeters)

Shelf Above Fireplace With Rear Venting

Shelf Above Fireplace With Top Venting

Figure 9 - Shelf Height Minimum Clearances

14

8-1/4Protected wall shown in white

 

(356)

(209)

Figure 10

 

 

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Image 9
Contents OTL Report No -F-29-5 700,043M REV. a 06/2008Table of Contents SSDVT/R-3328 ModelsElectronic Models Natural and Propane Gas Model SeriesMassachusetts Horizontal Vent Re- quirements MassachusettsNew York City, New York SIT MillivoltLocation Cold Climate InsulationManufactured Home Requirements Horizontal Vent Termination Clearances Vent Termination ClearancesVertical Vent Termination Clearances Roof Pitch FeetMeter/regulator assembly Canadian Installation US Installation= Clearance to service regulator vent outlet Feet 91cm Inches 30cmWall Finishes / Surrounds / Mantels Minimum Clearances to CombustiblesAppliance and Vent Clearances SpacersTypical Installation Sequence Detailed Installation StepsFraming Routing Gas LineTop View Front ViewRight Side View Proper Sizing of Gas Line Fireplace Framing specificationsSchedule 40 / Black Iron Pipe Length feetInstallation of Vent Restrictor Install the Vent System General InformationThese fireplaces must be vented directly to the outside Select Venting System Horizontal or VerticalVertical Straight Installation Vertical Termination Systems RoofEffective Vent Length Attach vent components to each other Vertical Offset InstallationIf the vent system extends more than 5 feet Pitch10-1/2 267 mm 305 mm 267 mm 451 mm610 305 219 829 914 438 Vertical Vent FIGURES/TABLESTable B Maximum Minimum Feet Meter 524 Elbow Only 305 048 610 572 914 096 219Maximum Minimum Feet Meter Table CMeter 524 610 305 048 219 572 829 914 096 438 Table D + H1 Maximum MinimumSee on Page 14 or on Install Firestop/Spacer at exterior wall Install the Square Termination SV4.5HT-2 or SF4.5HT-2See on Page 11 for Min Horizontal Vent FIGURES/TABLES Horizontal Vent Figures / Tables Square termination SV4.5HT-2 shown Pull and extend outer flexible vent pipe Install the Outer Flex PipeFlexible Vent Section Attach Flex Vent to TerminationWiring Optional Forced Air Blower Kit Field WiringSIT and Honeywell Millivolt Wiring See FigureSchematic Representation Only Connecting Gas LineChecking Appliance Opera- tion Reinstalling Control Compartment DoorSIT and Honeywell Millivolt Appliance Checkout SIT Gas ValveInstall Logs, Volcanic Stone Electronic Appliance CheckoutGlowing Embers Glowing Embers Firebox Accessories / PartsInstalling Glass Enclosure Panels Installing the Glass DoorBurner Adjustments Flame Appearance and sooting Air Shutter Adjustment GuidelinesHood Installation Burner Air Shutter Adjustment ProcedureFinishing Requirements Wall Details Refer to FigureCat. No Model Description Closed Top Shroud Termination Kits Cat. NoModel Description Listed Secure Flex ComponentsListed Secure Vent Components All compressed flex vents can be expanded up to two timesMillivolt Appliances SIT Systems Adjusting KnobSIT Millivolt Gas Valve Pilot for SIT Millivolt Gas ValveFlare Nut Clip Ignitor Assembly

SSDV-3328 specifications

TOA Electronics SSDV-3328 is an advanced digital mixing amplifier designed to provide high-quality sound reinforcement for various applications, including commercial facilities, educational institutions, and public address systems. This versatile amplifier combines several key features and cutting-edge technologies to deliver exceptional audio performance and flexibility.

One of the standout characteristics of the SSDV-3328 is its robust power output. With a rating of 150 watts per channel, it is capable of driving a variety of speaker setups, ensuring that sound coverage is both powerful and consistent across large areas. This makes it an ideal choice for venues such as auditoriums, conference rooms, and exhibition halls.

The SSDV-3328 offers a unique blend of analog and digital input options, allowing seamless integration with various audio sources. It supports connectivity through balanced XLR inputs, RCA, and even digital input formats, providing users with the capabilities needed to connect microphones, musical instruments, and playback devices. This flexibility is invaluable for professionals who require adaptable solutions for different audio setups.

Equipped with TOA's advanced DSP (Digital Signal Processing) technology, the amplifier provides enhanced audio quality and control. Users can benefit from features such as graphic equalization, delay settings, and limiting, which enable precise tuning of the audio output to match the acoustics of any space. This capability ensures that the audio remains clear and intelligible, regardless of the complexity of the setup.

Another noteworthy feature of the SSDV-3328 is its built-in feedback suppression technology, designed to minimize feedback issues that can occur in live sound situations. This not only enhances the listening experience but also reduces the workload on sound technicians during events.

The design of the SSDV-3328 emphasizes reliability and ease of use. Its intuitive control panel includes well-organized knobs and switches for quick adjustments, while status indicators provide real-time feedback on system performance. Additionally, the lightweight and compact construction of the amplifier makes it easy to transport and install, meeting the demands of both permanent installations and portable setups.

In summary, TOA Electronics SSDV-3328 stands out in the realm of digital mixing amplifiers, offering powerful output, versatile connectivity, advanced DSP features, and a commitment to audio quality. Whether used in commercial spaces or live events, this amplifier is designed to deliver performance that meets the highest standards in sound reinforcement. Its thoughtful design and innovative technologies make it a reliable choice for audio professionals seeking a top-tier mixing amplifier.