TOA Electronics SSDV-3328 SSDVT/R-3328, Electronic Models, 17,500, Gas Pressure All Models

Page 3

These appliances are designed to operate on natural or propane gas only. To operate on Propane Gas a field converion is necessary (see Pages 34 to 36). Do not use any other fuels. The use of other fuels, or combination of fuels, will degrade the performance of this system and may be dangerous.

These fireplaces are designed as supplemen- tal heaters. Therefore, it is advisable to have an alternate heat source when installed in a dwelling.

Millivolt Models - The millivolt appliances are manually controlled and feature a spark igniter (piezo) that allows the appliance's pilot gas to be lit without the use of matches or batteries. This system provides continued service in the event of a power outage.

Millivolt models come standard with a manu- ally-modulated gas valve; flame appearance and heat output can be controlled at the gas valve. The BTU Input for these appliances is shown in Table 1.

Input (BTU) Manually-Modulated Gas Valves (millivolt models)

NATURAL & PROPANE GAS

Models

Input Rate (BTU / HR)

 

 

SSDVT/R-3328

17,500 high

13,500 low

 

 

 

Table 1

Electronic Models

Electronic models have a fixed rate gas valve. Input of electronic models is shown in Table 2.

Electronic Models with Fixed Rate Gas Valve

Natural and Propane Gas

Model Series

Input Rate (BTU / HR)

 

 

SSDVT/R-3328

17,500

 

 

Table 2

Gas Pressure - All Models

Tables 3, 4 and 5 show the appliances' gas pressure requirements:

Inlet Gas Supply Pressure

(all models)

 

Fuel #

 

Minimum

Maximum

 

 

 

 

 

 

 

 

 

 

Natural Gas

 

5.0" WC

10.5" WC

 

 

 

(1.24 kPa)

(2.61 kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Propane

 

11.0" WC

13.0" WC

 

 

 

(2.74 kPa)

(3.23 kPa)

 

 

 

 

 

 

 

Table 3

 

 

 

 

 

 

 

 

 

 

 

Manifold Gas Supply Pressure

 

 

 

 

(millivolt models)

 

 

 

 

 

 

 

 

 

 

Fuel #

 

 

Low

 

High

 

 

 

 

 

 

 

 

 

Natural

 

(Lo) 2.2" WC

 

(Hi) 3.5" WC

 

 

Gas

 

 

(.55 kPa)

 

(.87 kPa)

 

 

 

 

 

 

 

 

 

Propane

 

(Lo) 6.3" WC

 

(Hi) 10.0" WC

 

 

 

 

(1.57 kPa)

 

(2.49 kPa)

 

 

 

 

 

 

 

Table 4

Manifold Gas Supply Pressure

(electronic models)

Fuel #

Manifold Pressure

 

 

Natural Gas

3.5" WC (.87 kPa)

 

 

Propane

10.0" WC (2.49 kPa)

 

 

Table 5

Test gauge connections are provided on the front of the millivolt gas control valve, identi- fied IN for the inlet and OUT for the manifold side. A 1/8" NPT Test gauge connection is provided at the inlet and outlet side of the electronic gas control valve.

These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

These appliances and their individual shut-off valves must be disconnected from the gas supply piping system during any pressure testing of that system at pressures greater than 1/2 psig (3.5 kPa).

Orifice Sizes - Sea Level to High Altitude (All Models)

These appliances are tested and approved for installation at elevations of 0-4500 feet (0-1372 meters) above sea level using the standard burner orifice sizes (marked with an "*" in Table 6 ). For elevations above 4500 feet, contact your gas supplier or qualified service technician . Install the appliance according to the regulations of the local authorities having jurisdiction and, in the USA, the National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition or, in Canada, the CAN1-B149.1 and .2 codes - latest edition.

Burner Orifice Sizes

Elevation 0-4500 feet ( 0-1372 meters)

Model

Natural

Propane

Gas

Gas

Series

drill size (inches)

drill size (inches)

 

 

 

SSDVT/R-3328

#45 *

(0.048") *

 

 

 

* Standard size installed at factory

Table 6

Image 3
Contents OTL Report No -F-29-5 700,043M REV. a 06/2008Table of Contents Natural and Propane Gas Model Series ModelsSSDVT/R-3328 Electronic ModelsSIT Millivolt MassachusettsMassachusetts Horizontal Vent Re- quirements New York City, New YorkLocation Cold Climate InsulationManufactured Home Requirements Roof Pitch Feet Vent Termination ClearancesHorizontal Vent Termination Clearances Vertical Vent Termination ClearancesInches 30cm Canadian Installation US InstallationMeter/regulator assembly = Clearance to service regulator vent outlet Feet 91cmSpacers Minimum Clearances to CombustiblesWall Finishes / Surrounds / Mantels Appliance and Vent ClearancesRouting Gas Line Detailed Installation StepsTypical Installation Sequence FramingTop View Front ViewRight Side View Length feet Fireplace Framing specificationsProper Sizing of Gas Line Schedule 40 / Black Iron PipeSelect Venting System Horizontal or Vertical Install the Vent System General InformationInstallation of Vent Restrictor These fireplaces must be vented directly to the outsideVertical Straight Installation Vertical Termination Systems RoofEffective Vent Length Attach vent components to each other Vertical Offset Installation267 mm 451 mm PitchIf the vent system extends more than 5 feet 10-1/2 267 mm 305 mm524 Elbow Only 305 048 610 572 914 096 219 Vertical Vent FIGURES/TABLES610 305 219 829 914 438 Table B Maximum Minimum Feet MeterTable D + H1 Maximum Minimum Table CMaximum Minimum Feet Meter Meter 524 610 305 048 219 572 829 914 096 438See on Page 14 or on Install Firestop/Spacer at exterior wall Install the Square Termination SV4.5HT-2 or SF4.5HT-2See on Page 11 for Min Horizontal Vent FIGURES/TABLES Horizontal Vent Figures / Tables Square termination SV4.5HT-2 shown Attach Flex Vent to Termination Install the Outer Flex PipePull and extend outer flexible vent pipe Flexible Vent SectionSee Figure Field WiringWiring Optional Forced Air Blower Kit SIT and Honeywell Millivolt WiringSchematic Representation Only Connecting Gas LineSIT Gas Valve Reinstalling Control Compartment DoorChecking Appliance Opera- tion SIT and Honeywell Millivolt Appliance CheckoutInstall Logs, Volcanic Stone Electronic Appliance CheckoutGlowing Embers Glowing Embers Firebox Accessories / PartsAir Shutter Adjustment Guidelines Installing the Glass DoorInstalling Glass Enclosure Panels Burner Adjustments Flame Appearance and sootingRefer to Figure Burner Air Shutter Adjustment ProcedureHood Installation Finishing Requirements Wall DetailsCat. No Model Description Closed Top Shroud Termination Kits Cat. NoAll compressed flex vents can be expanded up to two times Listed Secure Flex ComponentsModel Description Listed Secure Vent ComponentsPilot for SIT Millivolt Gas Valve Adjusting KnobMillivolt Appliances SIT Systems SIT Millivolt Gas ValveFlare Nut Clip Ignitor Assembly

SSDV-3328 specifications

TOA Electronics SSDV-3328 is an advanced digital mixing amplifier designed to provide high-quality sound reinforcement for various applications, including commercial facilities, educational institutions, and public address systems. This versatile amplifier combines several key features and cutting-edge technologies to deliver exceptional audio performance and flexibility.

One of the standout characteristics of the SSDV-3328 is its robust power output. With a rating of 150 watts per channel, it is capable of driving a variety of speaker setups, ensuring that sound coverage is both powerful and consistent across large areas. This makes it an ideal choice for venues such as auditoriums, conference rooms, and exhibition halls.

The SSDV-3328 offers a unique blend of analog and digital input options, allowing seamless integration with various audio sources. It supports connectivity through balanced XLR inputs, RCA, and even digital input formats, providing users with the capabilities needed to connect microphones, musical instruments, and playback devices. This flexibility is invaluable for professionals who require adaptable solutions for different audio setups.

Equipped with TOA's advanced DSP (Digital Signal Processing) technology, the amplifier provides enhanced audio quality and control. Users can benefit from features such as graphic equalization, delay settings, and limiting, which enable precise tuning of the audio output to match the acoustics of any space. This capability ensures that the audio remains clear and intelligible, regardless of the complexity of the setup.

Another noteworthy feature of the SSDV-3328 is its built-in feedback suppression technology, designed to minimize feedback issues that can occur in live sound situations. This not only enhances the listening experience but also reduces the workload on sound technicians during events.

The design of the SSDV-3328 emphasizes reliability and ease of use. Its intuitive control panel includes well-organized knobs and switches for quick adjustments, while status indicators provide real-time feedback on system performance. Additionally, the lightweight and compact construction of the amplifier makes it easy to transport and install, meeting the demands of both permanent installations and portable setups.

In summary, TOA Electronics SSDV-3328 stands out in the realm of digital mixing amplifiers, offering powerful output, versatile connectivity, advanced DSP features, and a commitment to audio quality. Whether used in commercial spaces or live events, this amplifier is designed to deliver performance that meets the highest standards in sound reinforcement. Its thoughtful design and innovative technologies make it a reliable choice for audio professionals seeking a top-tier mixing amplifier.