TOA Electronics SSDV-3328 Canadian Installation US Installation, Inches 30cm, Inches 458mm

Page 8

Exterior HORIZONTAL Vent TERMINATION Clearance Requirements

*See Item D in the Text Below.

Exterior Wall

Center Line

of Termination

 

 

*18

 

 

Horizontal

V

 

 

 

Termination

 

 

18Ventilated Soffit

Inside Corner

Detail D

 

B

 

 

C

 

 

 

V

L

 

 

Fixed

 

 

 

 

 

 

 

Closed

 

 

F

V

Window

 

 

 

 

 

 

C

 

V

 

 

 

 

C

C

 

 

 

A

 

X = Air Supply Inlet

V

NOTE: Local Codes Or Regulations

May Require Different Clearances.

 

Inside

 

NOTE: Location Of The Vent Termination

N

 

P

N

 

 

 

 

 

 

Corner Detail

 

Must Not Interfere With Access To The

 

 

 

O

 

Electrical Service.

 

 

 

 

G

 

 

 

 

 

Q

V

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

A

= 9

in U.S.

 

 

 

 

 

 

 

= 12 in Canada

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

3 ft.

 

 

 

 

 

B

 

 

 

X

 

 

 

 

D

 

 

 

A

A

 

 

 

 

 

 

 

 

 

 

 

 

V

Operable

 

 

 

 

 

 

 

 

 

Window

 

 

3 ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

J

 

 

M

 

 

 

B

B

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I

 

 

 

= Vent Termination

= Area where Termination is not Permitted

 

 

 

 

V

 

Canadian Installation*

US Installation**

 

 

 

A = Clearance above grade, veranda, porch, deck, or balcony.

12 inches (30cm)*

12 inches (30cm)**

 

 

 

B = Clearance to window or door that may be opened.

6 inches (15cm) for appliances

6 inches (15cm) for appliances

 

< 10,000 Btuh (3kW), 12 inches (30cm)

< 10,000 Btuh (3kW), 9 inches (23cm)

 

for appliances > 10,000 Btuh (3kW)

for appliances > 10,000 Btuh (3kW) and

 

 

< 50,000 Btuh (15kW), 12 inches (30cm)

 

 

for appliances > 50,000 Btuh (15kW)**

 

 

 

C = Clearance to permanently closed window

12 inches (305mm) recommended to

9 inches (229mm) recommended to

 

prevent window condensation

prevent window condensation

D = Vertical clearance to ventilated soffit located above the

18 inches (458mm)

18 inches (458mm)

termination within a horizontal distance of 18 inches (458mm)

 

 

from the center line of the termination

 

 

E = Clearance to unventilated soffit***

12 inches (305mm)

12 inches (305mm)

 

 

 

F = Clearance to outside corner

5 inches (12.7cm) minimum

5 inches (12.7cm) minimum

 

 

 

G = Clearance to inside corner

6 inches (15.2cm) minimum

6 inches (15.2cm) minimum

 

 

 

H = Clearance to each inside of center line extended above

3 feet (91cm) within a height of 15 feet

3 feet (91cm) within a height of 15 feet

meter/regulator assembly

above the meter/regulator assembly*

above the meter/regulator assembly**

I = Clearance to service regulator vent outlet

3 feet (91cm)*

3 feet (91cm)**

 

 

 

J = Clearance to nonmechanical air supply inlet to building or

6 inches (15cm) for appliances

6 inches (15cm) for appliances

the combustion air inlet to any other appliance

< 10,000 Btuh (3kW), 12 inches (30cm)

< 10,000 Btuh (3kW), 9 inches (23cm)

 

for appliances > 10,000 Btuh (3kW)

for appliances > 10,000 Btuh (3kW) and

 

 

< 50,000 Btuh (15kW), 12 inches (30cm)

 

 

for appliances > 50,000 Btuh (15kW)**

 

 

 

K = Clearance to a mechanical air supply inlet

6 feet (1.83m)*

3 feet (91cm) above if within 10 feet

 

 

(3m) horizontally**

L = Clearance above paved sidewalk or paved diveway located

7 feet (2.13m)‡

7 feet (2.13m)‡

on public property

 

 

M = Clearance under veranda, porch, deck or balcony

12 inches (30cm)*‡

12 inches (30cm)‡

N = Depth of Alcove (Maximum)

6 feet (1.83m)*

6 feet (1.83m)**

O = Clearance to Termination (Alcove)

6 inches (15.2mm)*

6 inches (15.2mm)**

 

 

 

P = Width of Alcove (Minimum)

3 feet (91cm)*

3 feet (91cm)*

 

 

 

Q = Clearance to Combustible Above (Alcove)

18 inches (457mm)*

18 inches (457mm)**

* In accordance with the current CSA-B149.1 National Gas And Propane Installation Code. ** In accordance with the curent ANSI SZ223.1/NFPA 54 National Fuel Gas Codes.

*** Clearance required to vinyl soffit material - 30 inches (76cm) minimum.

‡ A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

*‡ Only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor:

Figure 7

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Image 8
Contents 700,043M REV. a 06/2008 OTL Report No -F-29-5Table of Contents Models SSDVT/R-3328Electronic Models Natural and Propane Gas Model SeriesMassachusetts Massachusetts Horizontal Vent Re- quirementsNew York City, New York SIT MillivoltCold Climate Insulation LocationManufactured Home Requirements Vent Termination Clearances Horizontal Vent Termination ClearancesVertical Vent Termination Clearances Roof Pitch FeetCanadian Installation US Installation Meter/regulator assembly= Clearance to service regulator vent outlet Feet 91cm Inches 30cmMinimum Clearances to Combustibles Wall Finishes / Surrounds / MantelsAppliance and Vent Clearances SpacersDetailed Installation Steps Typical Installation SequenceFraming Routing Gas LineRight Side View Top ViewFront View Fireplace Framing specifications Proper Sizing of Gas LineSchedule 40 / Black Iron Pipe Length feetInstall the Vent System General Information Installation of Vent RestrictorThese fireplaces must be vented directly to the outside Select Venting System Horizontal or VerticalEffective Vent Length Vertical Straight InstallationVertical Termination Systems Roof Vertical Offset Installation Attach vent components to each otherPitch If the vent system extends more than 5 feet10-1/2 267 mm 305 mm 267 mm 451 mmVertical Vent FIGURES/TABLES 610 305 219 829 914 438Table B Maximum Minimum Feet Meter 524 Elbow Only 305 048 610 572 914 096 219Table C Maximum Minimum Feet MeterMeter 524 610 305 048 219 572 829 914 096 438 Table D + H1 Maximum MinimumSee on Page 14 or on See on Page 11 for Min Install Firestop/Spacer at exterior wallInstall the Square Termination SV4.5HT-2 or SF4.5HT-2 Horizontal Vent FIGURES/TABLES Horizontal Vent Figures / Tables Square termination SV4.5HT-2 shown Install the Outer Flex Pipe Pull and extend outer flexible vent pipeFlexible Vent Section Attach Flex Vent to TerminationField Wiring Wiring Optional Forced Air Blower KitSIT and Honeywell Millivolt Wiring See FigureConnecting Gas Line Schematic Representation OnlyReinstalling Control Compartment Door Checking Appliance Opera- tionSIT and Honeywell Millivolt Appliance Checkout SIT Gas ValveGlowing Embers Install Logs, Volcanic StoneElectronic Appliance Checkout Firebox Accessories / Parts Glowing EmbersInstalling the Glass Door Installing Glass Enclosure PanelsBurner Adjustments Flame Appearance and sooting Air Shutter Adjustment GuidelinesBurner Air Shutter Adjustment Procedure Hood InstallationFinishing Requirements Wall Details Refer to FigureCat. No Model Description Cat. No Closed Top Shroud Termination KitsListed Secure Flex Components Model DescriptionListed Secure Vent Components All compressed flex vents can be expanded up to two timesAdjusting Knob Millivolt Appliances SIT SystemsSIT Millivolt Gas Valve Pilot for SIT Millivolt Gas ValveIgnitor Assembly Flare Nut Clip

SSDV-3328 specifications

TOA Electronics SSDV-3328 is an advanced digital mixing amplifier designed to provide high-quality sound reinforcement for various applications, including commercial facilities, educational institutions, and public address systems. This versatile amplifier combines several key features and cutting-edge technologies to deliver exceptional audio performance and flexibility.

One of the standout characteristics of the SSDV-3328 is its robust power output. With a rating of 150 watts per channel, it is capable of driving a variety of speaker setups, ensuring that sound coverage is both powerful and consistent across large areas. This makes it an ideal choice for venues such as auditoriums, conference rooms, and exhibition halls.

The SSDV-3328 offers a unique blend of analog and digital input options, allowing seamless integration with various audio sources. It supports connectivity through balanced XLR inputs, RCA, and even digital input formats, providing users with the capabilities needed to connect microphones, musical instruments, and playback devices. This flexibility is invaluable for professionals who require adaptable solutions for different audio setups.

Equipped with TOA's advanced DSP (Digital Signal Processing) technology, the amplifier provides enhanced audio quality and control. Users can benefit from features such as graphic equalization, delay settings, and limiting, which enable precise tuning of the audio output to match the acoustics of any space. This capability ensures that the audio remains clear and intelligible, regardless of the complexity of the setup.

Another noteworthy feature of the SSDV-3328 is its built-in feedback suppression technology, designed to minimize feedback issues that can occur in live sound situations. This not only enhances the listening experience but also reduces the workload on sound technicians during events.

The design of the SSDV-3328 emphasizes reliability and ease of use. Its intuitive control panel includes well-organized knobs and switches for quick adjustments, while status indicators provide real-time feedback on system performance. Additionally, the lightweight and compact construction of the amplifier makes it easy to transport and install, meeting the demands of both permanent installations and portable setups.

In summary, TOA Electronics SSDV-3328 stands out in the realm of digital mixing amplifiers, offering powerful output, versatile connectivity, advanced DSP features, and a commitment to audio quality. Whether used in commercial spaces or live events, this amplifier is designed to deliver performance that meets the highest standards in sound reinforcement. Its thoughtful design and innovative technologies make it a reliable choice for audio professionals seeking a top-tier mixing amplifier.