Detailed Installation Steps

The appliance is shipped with all gas controls and components installed and pre-wired. Re- move the shipping carton, exposing the front glass door. Remove the top and bottom louvered control panel per instructions on Page 27 (see Control Compartment Access / Louver Panel Instructions). Remove the cardboard from underneath the pressure relief plates, in area behind top louver panel (see Figure 11). Open the two latches (located under the firebox floor) securing the glass door. Remove the door by tilting it outward at the bottom and lifting it up. Set the door aside protecting it from inadvertent damage. See Figure 54 on Page 30.

Pressure Relief Plates

 

REMOVE

REMOVE

CARDBOARD

CARDBOARD

BEFOREUSING

BEFOREUSING

 

Remove Cardboard Before

Using Appliance

 

Figure 11

 

TYPICAL INSTALLATION SEQUENCE

The typical sequence of installation follows, however, each installation is unique resulting in variations to those described.

See the Page numbers references in the follow- ing steps for detailed procedures.

Step 1. (Page 10) Construct the appliance framing. Position the appliance within the framing and secure with nailing brackets.

Step 2. (Page 10) Route gas supply line to appliance location.

Step 3. (Page 13) Install the vent system and exterior termination.

Step 4. (Page 25) Field Wiring

a. Millivolt Appliances – Install the operating control switch (not factory provided) and bring in electrical service line for forced air circulating blower (optional equipment). b. Electronic Appliances – Field wire and install

operating control switch.

Step 5. (Page 25) Install blower kit (optional equipment).

Step 6. (Page 26) Make connection to gas sup- ply.

Step 7. (Page 27) Checkout appliance operation. Step 8. (Page 28) Install the logs, decorative

volcanic stone and glowing embers.

Step 9. (Page 30) Install glass door frame as- sembly.

Step10.(Page30) Adjustburner to ensure proper flame appearance.

Step 11. (Page 31) Install the hoods.

Step 1. Framing

Frame these appliances as illustrated in Figure 14 on Page 11, unless the appliance is to be installed in a corner. See Figure 15 on Page

12for corner framing installations. All framing details must allow for a minimum clearance to combustible framing members as shown in Table 8 on Page 9.

If the appliance is to be elevated above floor level, a solid continuous platform must be constructed.

Headers may be in direct contact with the appliance top spacers but must not be sup- ported by them or notched to fit around them. All construction above the appliance must be self supporting. DO NOT use the appliance for structural support.

Thefireplaceshouldbesecuredtothesideframing members using the unit's nailing flanges - one top and bottom on each side of the fireplace front. See Figure 12. Use 8d nails or their equivalent.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Side

Unit Nailing Flange

(No clearance to

Framing

combustible

 

framing is required)

Left Side Front Corner of Fireplace Shown

(Right Side Requirements the Same)

Unit Being Secured By Its Nailing Flanges

 

To The Framing

Note: The nailing flanges, combustible members

and screw heads located in areas directly adjacent

to the nailing flanges, are EXEMPT from the 1/2”

clearance to combustible requirements for the

firebox outer wrapper. Combustible framing may be

in direct contact with the nailing flanges and may

be located closer than 1/2” from screw heads and

the firebox wrapper in areas adjacent to the nailing

flanges. Frame the opening to the exact dimensions

specified in the framing details of this manual.

Figure 12

Step 2. Routing Gas Line

Route a 1/2" (13 mm) gas line along the inside of the right side framing as shown in Tables. Gas lines must be routed, constructed and made of materials that are in strict accordance with local codes and regulations. All appliances are factory-equipped with a flexible gas line con- nector and 1/2 inch shutoff valve. (See Step 6 on Page 26).

Right Side Front Corner of Fire- place Framing

3"

6 1/2"(76 mm)

(152 mm)

Also see Figure 14.

Figure 13 - ROUTE GAS LINE

Continued on Page 12.

Image 10
Contents 700,043M REV. a 06/2008 OTL Report No -F-29-5Table of Contents Electronic Models ModelsSSDVT/R-3328 Natural and Propane Gas Model SeriesNew York City, New York MassachusettsMassachusetts Horizontal Vent Re- quirements SIT MillivoltCold Climate Insulation LocationManufactured Home Requirements Vertical Vent Termination Clearances Vent Termination ClearancesHorizontal Vent Termination Clearances Roof Pitch Feet= Clearance to service regulator vent outlet Feet 91cm Canadian Installation US InstallationMeter/regulator assembly Inches 30cmAppliance and Vent Clearances Minimum Clearances to CombustiblesWall Finishes / Surrounds / Mantels SpacersFraming Detailed Installation StepsTypical Installation Sequence Routing Gas LineFront View Top ViewRight Side View Schedule 40 / Black Iron Pipe Fireplace Framing specificationsProper Sizing of Gas Line Length feetThese fireplaces must be vented directly to the outside Install the Vent System General InformationInstallation of Vent Restrictor Select Venting System Horizontal or VerticalVertical Termination Systems Roof Vertical Straight InstallationEffective Vent Length Vertical Offset Installation Attach vent components to each other10-1/2 267 mm 305 mm PitchIf the vent system extends more than 5 feet 267 mm 451 mmTable B Maximum Minimum Feet Meter Vertical Vent FIGURES/TABLES610 305 219 829 914 438 524 Elbow Only 305 048 610 572 914 096 219Meter 524 610 305 048 219 572 829 914 096 438 Table CMaximum Minimum Feet Meter Table D + H1 Maximum MinimumSee on Page 14 or on Install the Square Termination SV4.5HT-2 or SF4.5HT-2 Install Firestop/Spacer at exterior wallSee on Page 11 for Min Horizontal Vent FIGURES/TABLES Horizontal Vent Figures / Tables Square termination SV4.5HT-2 shown Flexible Vent Section Install the Outer Flex PipePull and extend outer flexible vent pipe Attach Flex Vent to TerminationSIT and Honeywell Millivolt Wiring Field WiringWiring Optional Forced Air Blower Kit See FigureConnecting Gas Line Schematic Representation OnlySIT and Honeywell Millivolt Appliance Checkout Reinstalling Control Compartment DoorChecking Appliance Opera- tion SIT Gas ValveElectronic Appliance Checkout Install Logs, Volcanic StoneGlowing Embers Firebox Accessories / Parts Glowing EmbersBurner Adjustments Flame Appearance and sooting Installing the Glass DoorInstalling Glass Enclosure Panels Air Shutter Adjustment GuidelinesFinishing Requirements Wall Details Burner Air Shutter Adjustment ProcedureHood Installation Refer to FigureCat. No Model Description Cat. No Closed Top Shroud Termination KitsListed Secure Vent Components Listed Secure Flex ComponentsModel Description All compressed flex vents can be expanded up to two timesSIT Millivolt Gas Valve Adjusting KnobMillivolt Appliances SIT Systems Pilot for SIT Millivolt Gas ValveIgnitor Assembly Flare Nut Clip

SSDV-3328 specifications

TOA Electronics SSDV-3328 is an advanced digital mixing amplifier designed to provide high-quality sound reinforcement for various applications, including commercial facilities, educational institutions, and public address systems. This versatile amplifier combines several key features and cutting-edge technologies to deliver exceptional audio performance and flexibility.

One of the standout characteristics of the SSDV-3328 is its robust power output. With a rating of 150 watts per channel, it is capable of driving a variety of speaker setups, ensuring that sound coverage is both powerful and consistent across large areas. This makes it an ideal choice for venues such as auditoriums, conference rooms, and exhibition halls.

The SSDV-3328 offers a unique blend of analog and digital input options, allowing seamless integration with various audio sources. It supports connectivity through balanced XLR inputs, RCA, and even digital input formats, providing users with the capabilities needed to connect microphones, musical instruments, and playback devices. This flexibility is invaluable for professionals who require adaptable solutions for different audio setups.

Equipped with TOA's advanced DSP (Digital Signal Processing) technology, the amplifier provides enhanced audio quality and control. Users can benefit from features such as graphic equalization, delay settings, and limiting, which enable precise tuning of the audio output to match the acoustics of any space. This capability ensures that the audio remains clear and intelligible, regardless of the complexity of the setup.

Another noteworthy feature of the SSDV-3328 is its built-in feedback suppression technology, designed to minimize feedback issues that can occur in live sound situations. This not only enhances the listening experience but also reduces the workload on sound technicians during events.

The design of the SSDV-3328 emphasizes reliability and ease of use. Its intuitive control panel includes well-organized knobs and switches for quick adjustments, while status indicators provide real-time feedback on system performance. Additionally, the lightweight and compact construction of the amplifier makes it easy to transport and install, meeting the demands of both permanent installations and portable setups.

In summary, TOA Electronics SSDV-3328 stands out in the realm of digital mixing amplifiers, offering powerful output, versatile connectivity, advanced DSP features, and a commitment to audio quality. Whether used in commercial spaces or live events, this amplifier is designed to deliver performance that meets the highest standards in sound reinforcement. Its thoughtful design and innovative technologies make it a reliable choice for audio professionals seeking a top-tier mixing amplifier.