Vermont Casting VCS3506, VCS6006, VCS5016 Natural GAS Supply Connection To Connect, To Disconnect

Page 11

Gas Hookup

NATURAL GAS SUPPLY CONNECTION

TO CONNECT:

1.Push back the Sleeve on the Socket as shown below (see Fig. 6a).

2.Insert Plug and release the Sleeve (see Fig. 6b).

3.Push the Plug until Sleeve snaps forward to lock the Plug in the Socket.

WARNING: Always conduct the following safety tests before lighting the Grill, to prevent a possible fire or explosion (see leak test below).

TO DISCONNECT:

1. Push Sleeve back and pull the Plug out.

Retract Sleeve

Fig. 6a

Release Sleeve

 

Release Sleeve

Fig. 6b

 

TESTING FOR GAS LEAKS

Before attempting to operate this Grill:

1.Always confirm that all burner control knobs are in the OFF position.

2.Always connect the gas supply hose first and then open the gas shutoff valve.

3.Always use a brush or spray bottle to apply a 50/50 solution of liquid soap and water to all connection points (see Fig. 5) to test for gas leaks. Never use a match or open flame for that purpose.

4.Always look for bubbles to appear, as the appearance of bubbles will indicate a gas leak. Always turn off the gas immediately and tighten the connection, if you find that a leak exists.

5.Always repeat this procedure until no further gas leaks are found to exist, before lighting the Grill.

6.Never attempt to light this Grill, however, if a leak cannot be stopped. Always call your gas supplier promptly to obtain assistance.

WARNINGS:

Always consult the Rating Label on the back of the Grill to confirm that it has already been configured to burn Natural Gas.

All gas supply plumbing should be performed only by a qualified service agency. In the U.S., the supply connection must be made in accordance with local code or, in the absence of local codes, with the national fuel gas codes, ANSI Z223.1/NFPA54. In Canada, the supply connection shall be carried out in accordance with the provincial authorities having jurisdiction and in accordance with the requirements of the CAN/ CGA 1-B149.1 installation code. A shutoff value must be installed between the gas grill and the main supply. For natural gas, use a 3/8” or 1/2” natural gas supply line capable of an a input of up to 100,000 BTUs (depending on the model).

Always disconnect the Grill and close its individual manual shutoff valve, when conducting pressure tests of the gas supply piping system at pressures which exceed 1/2 psi (3.5 kPa).

Always isolate the Grill from the gas supply piping system by closing its individual manual shutoff valve.

Page 5

Image 11
Contents USER’S Manual for Models Page Signal Words Safe Locations for USE of this Outdoor Grill Safe USE of Natural GAS Safe USE of LP Propane GASPrevention of Burns SafetyElectrical Safety Table of Contents Fuels Additional Warnings Safety Hooking Up to the LP Propane Gas Supply For Your Safety LP Propane GAS Supply ConnectionGas Hookup To Disconnect Testing for GAS LeaksNatural GAS Supply Connection To Connect Activating the Igniter Electronic Ignition System OperationControl Functions Propane Tank Valve Burner Control Valves see FigLighting the Main Burners Match Lighting the Main Burners Turning the Burners OFFFLARE-UPS Match Lighting the Rotisserie Burner Lighting the Rotisserie Burner if equippedTo Start the Rotisserie Burner Rotisserie Setup if equipped Shutting the Burner OFF Lighting the Side Burner if equippedMethods of Cooking CookingPreparing Food for the Grill Grilling Tips Beef Cooking Time ChartSausage Vegetables Main Burner Care & MaintenanceCare & Cleaning Burners Cooking Grids Rotisserie Burner if equippedSide Burner if equipped Porcelain Enamel Castings Drip TrayStainless Steel Panels Problem Potential Cause Action Required Troubleshooting GuideIt may short out. Replace the electrode Year Warranty VCS3506BI / VCS5006BI Assembly Assemble Fascia Brackets Parts Required Burner Adjustment Assemble the Rear Panel Parts Required Assemble the Grease Tray Front and Handle Parts Required Assemble the Grill Unit to the Enclosure Install Internal Components and Knobs Parts Required