VCS3506BI / VCS5006BI Assembly |
|
|
|
|
| |||
|
|
|
|
| ||||
|
| VCS3506BI / VCS5006BI FRAMING DIMENSIONS |
| |||||
|
| O |
|
|
| F |
| |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| J |
|
|
| A |
|
|
| L |
| |
|
|
|
|
|
|
| K |
|
|
| D |
|
| G |
|
| |
|
| C |
|
|
|
|
| |
|
| E |
|
| H |
|
| |
|
|
|
|
|
|
| ||
|
| B |
|
|
|
|
| |
|
|
|
|
|
|
| M |
|
| Fig. 2 |
|
|
|
|
| ||
|
|
|
| I |
|
| N |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| Combustible Clearances | ||||||
|
| With ZC Insulated Jacket | ||||||
|
|
|
|
|
|
| ||
|
|
|
|
|
| |||
Ref. |
| VCS3506BI |
| VCS5006BI | VCS3506BI | VCS5006BI | ||
A |
|
| ||||||
B |
| 4" [101.6mm] |
| 4" [101.6mm] | 3" [76.2mm] | 3" [76.2mm] | ||
C |
| 2" [50.8mm] Dia. |
| 2" [50.8mm] Dia. | 2" [50.8mm] Dia. | 2" [50.8mm] Dia. | ||
D |
| 2 1/8" [54.0mm] |
| 2 1/8" [54.0mm] | 2 1/8" [54.0mm] | 2 1/8" [54.0mm] | ||
E |
| 3" [76.2mm] |
| 3" [76.2mm] | 3" [76.2mm] | 3" [76.2mm] | ||
F |
|
| ||||||
G |
|
| ||||||
H |
| 9" [228.6mm] |
| 9" [228.6mm] | 10" [254.0mm] | 10" [254.0mm] | ||
I |
|
| ||||||
J |
| 12" [304.8mm] |
| 12" [304.8mm] | 12" [304.8mm] | 12" [304.8mm] | ||
K |
| 18" [457.2mm] |
| 18" [457.2mm] | 18" [457.2mm] | 18" [457.2mm] | ||
L |
| 10" [254.0mm] |
| 10" [254.0mm] | 10" [254.0mm] | 10" [254.0mm] | ||
M |
|
| ||||||
N |
| 4" [101.6mm] Min. |
| 4" [101.6mm] Min. | 4" [101.6mm] Min. | 4" [101.6mm] Min. | ||
O |
| 4" [101.6mm] Min. |
| 4" [101.6mm] Min. | 4" [101.6mm] Min. | 4" [101.6mm] Min. |
Note: Ensure that your grill enclosure has been constructed according to the exact specifications shown in Fig.
2.If the enclosure is constructed of wood or other similar combustible materials, the use of the insulated jacket Model VCIJ35A or VCIJ50A is required.
If you have an L.P. model with a 20lb cylinder stored in the enclosure, ensure that there at least two air ventilation openings of 10sq inches 180 degrees apart and they are level with the cylinder valve. Another two openings with the same dimensions and distance are required to be level with the base of the cylinder. For other requirements, see section 1.7 of ANSI