TROUBLESHOOTING:
FRYING SYSTEM:
Should there be a problem with your machine, the following checks should be done prior to calling an Authorized Service Company. Make sure the machine is operated correctly and that the Computer or Digital Display (when
installed) is programmed accordingly.
Check these items before calling your Authorized Service Company
ITEM TO CHECK | HOW TO CHECK |
Power to machine | Check main power to machine (When applicable.) |
Press | |
| behind door |
Power switch on | Power switch should be in the ON position. (On RPB |
| machines ONLY the manual reset switch must be |
| pressed after there has been an interruption in power.) |
Gas to machine | Make sure gas supply line is connected |
Gas valve knob position | Should be in the appropriate position |
Fuses | Check for blown fuses. (Where applicable.) |
Check pilot | Make sure the pilot is lit |
| |
Locate the problem in the chart below then follow the instructions in the above chart. | |
PROBLEM | ITEM TO CHECK |
Machine will not run: | Power to machine (Where applicable.) |
No lights on the front panel |
|
Machine will not run: | |
Front panel lights are ON. | Gas to machine |
| Gas valve knob position |
Pilot will not light | |
| Gas to machine |
| Gas valve knob position |
Pilot lights: | Power switch ON |
Machine will not heat | Gas valve knob position |
| Fuses |
| Is Thermostat turned UP |
Machine will not maintain temp: |
|
Is machine still running? YES | Gas valve knob position |
NO | Check pilot |
Machine will not maintain temp: |
|
Is pilot lit? YES | Call Authorized Service Company |
NO | Relight pilot per the manual |
Oil temp too hot or Machine runs constantly | Check Thermostat calibration (Where applicable.) |
| Call Authorized Service Company |
Shortening is leaking from fry tank | Call Authorized Service Company |