Vermont Casting DVR28IN installation instructions General Venting Information Termination Location

Page 9

Vermont Castings DVR28 Direct Vent Gas Fireplace

General Venting Information - Termination Location

D

E

V

L

B

CFM145a

C

V�����

������

F

V

Operable

 

B

 

INSIDE

 

 

 

 

CORNER DETAIL

 

 

 

 

G

 

 

 

 

 

V

 

 

 

N

A

 

 

H

N

 

 

 

 

 

 

 

B

 

 

 

 

 

V

 

B

V

 

 

Operable

Fixed

 

 

 

 

Closed

 

 

 

 

 

 

 

 

 

 

 

B

M

 

B

V J

X

 

 

V K X

 

A

 

I

 

 

 

 

 

 

V VENT TERMINATION X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED

 

 

 

Canadian Installations1

US Installations2

 

A =

Clearance above grade, veranda, porch,

12” (30 cm)

12” (30 cm)

 

 

deck, or balcony

 

 

 

B = Clearance to window or door that may be

6” (15 cm) for appliances

6” (15 cm) for appliances

 

 

opened

< 10,000 Btuh (3kW), 12” (30 cm)

< 10,000 Btuh (3kW), 9”

 

 

 

for appliances > 10,000 Btuh (3kW) and

(23 cm) for appliances > 10,000

 

 

 

< 100,000 Btuh (30kW), 36” (91 cm)

Btuh (3kW) and < 50,000 Btuh

 

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30 cm) for

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

C = Clearance to permanently closed window

12” (305 mm) recommended to

12” (305 mm) recommended to

 

 

 

prevent window condensation

prevent window condensation

 

D = Vertical clearance to ventilated soffit located

 

 

 

 

above the terminal within a horizontal

18” (458 mm)

18” (458 mm)

 

 

distance of 2’ (610mm) from the center

 

 

 

 

line of the terminal

 

 

 

E = Clearance to unventilated soffit

12” (305 mm)

12” (305 mm)

 

F =

Clearance to outside corner

see next page

see next page

 

G = Clearance to inside corner (see next page)

see next page

see next page

 

H = Clearance to each inside of center line

3’ (91 cm) within a height of 15’ (5 m)

3’ (91 cm) within a height of 15’

 

 

extended above meter/regulator assembly

above the meter/regulator assembly

(5 m) above the meter/regulator

 

 

 

 

assy

 

I =

Clearance to service regulator vent outlet

3’ (91 cm)

3’ (91 cm)

 

J =

Clearance to nonmechanical air supply inlet

6” (15 cm) for appliances < 10,000 Btuh

6” (15 cm) for appliances

 

 

to building or the combustion air inlet to any

(3kW), 12” (30 cm) for appliances

< 10,000 Btuh (3kW), 9”

 

 

other appliances

> 10,000 Btuh (3kW) and < 100,000 Btuh

(23 cm) for appliances > 10,000

 

 

 

(30kW), 36” (91cm) for appliances

Btuh (3kW) and < 50,000 Btuh

 

 

 

> 100,000 Btuh (30kW)

(15kW), 12” (30 cm) for

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

K = Clearance to a mechanical air supply inlet

6’ (1.83 m)

3’ (91 cm) above if within 10

 

 

 

 

feet (3 m) horizontally

 

L =

Clearance above paved sidewalk or paved

7’ (2.13 m)†

7’ (2.13 m)†

 

 

driveway located on public property

 

 

 

M = Clearance under veranda, porch, deck or

12” (30 cm)‡

12” (30 cm)‡

 

 

balcony

 

 

N = Clearance above a roof shall extend a minimum of 24” (610 mm) above the highest point when it passes through the roof surface, and any other obstruction within a horizontal distance of 18” (450 mm).

1 In accordance with the current CSA-B149 Installation Codes

2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes

A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings

‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: NOTE: 1. Local codes or regulations may require different clearances.

2.The special venting system used on Direct Vent Fireplaces are certified as part of the appliance, with clearances tested and approved by the listing agency.

3.CFM Corporation assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

Fig. 11 Vent termination locations.

20012301

9

Image 9
Contents Direct Vent Model DVR28IN Table of Contents Installation & Operating Instructions Certified ToAnsi Z21.88-2005 / CSA Vented Gas Fireplace Heaters Fireplace specifications and framing dimensions DVR28 Fireplace DimensionsLocating Your Fireplace Installation Instructions PreparationMounting the Fireplace Clearance to Combustibles Gas Specifications Gas Line Installation Gas Inlet and Manifold Pressures High ElevationsInstallation Restrictor Plate InstallationLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes Twist Lock PipesRear Wall Venting Applications How to Use the Vent GraphExample a Example BZero clearance sleeve is only required for combustible walls Rear Wall Installation Twist Lock PipeTotal angular variation = Vertical Sidewall ApplicationsVertical Through-the-Roof Application Below Grade InstallationsPlace firestop spacers and secure Vertical Through-the-Roof InstallationMinimum termination to roof clearance Venting Components Glass Cleaning Window Frame Assembly RemovalOperating Instructions Glass InformationFlame & Temperature Adjustment Flame CharacteristicsInspecting the Venting System For Fireplaces equipped with AF4000 Gas Valve Lighting & Operating InstructionsLighting Instructions Turning Off the Gas to the ApplianceAF4000 Valve TroubleshootingIgniter operation Troubleshooting AF4000 ValveTroubleshooting AF4000 Valve Cleaning the Standing Pilot Control System MaintenanceFireplace May Be HOT Burner and Burner CompartmentDVR28 DescriptionCurve Face Kit Optional AccessoriesScreen Door Kit Model # ColorLimited Lifetime Warranty 67.6 64.3 Efficiency Ratings