Vermont Casting DVR28IN Gas Specifications, Gas Inlet and Manifold Pressures, High Elevations

Page 6

Vermont Castings DVR28 Direct Vent Gas Fireplace

Sheet Metal

Screws (8)

Wall Mounting Bracket

Secured to Walll

DVR28

Sheet Metal

 

Screws (4)

FP1785

Fig. 6 Secure fireplace to wall mounting bracket.

Gas Specifications

 

 

 

Max.

Min.

Air

 

 

 

Input

Input

Shutter

Model

Fuel

Gas Control

BTU/h

BTU/h

Setting

 

 

 

 

 

1/8”

DVR28IN

Nat.

Millivolt Hi/Lo

18,500

16,500

open

 

 

 

 

 

on sides

Gas Inlet and Manifold Pressures

 

Natural

Inlet Minimum

5.5” w.c.

Inlet Maximum

14.0” w.c.

Manifold Pressure

3.5” w.c.

High Elevations

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level.

For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the cur- rent ANSI Z223.1/NFPA 54 and/or local codes hav- ing jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m).

Remote ON/OFF Hi/Lo

Wall Mounted Transmitter

The DVR28 is equipped with a wireless transmitter. No wires are required.

Gas Line Installation

When purging the gas lines, the front win- dow frame assembly must be removed.

The gas pipeline can be brought in under the bottom of the fireplace. The gas line connections will be covered by bottom trim. Refer to Figure 7 for gas line dimen- sions. Use 1/2” rigid pipe. When gas line is in place un- der the fireplace, install supplied 1/2” FPT to 3/8” flare brass fitting. Connect preinstalled flex line on fireplace to brass fitting with 3/8” flare fitting on supply line.

The gas line connection can be made with 3/8” rigid pipe or an approved flex connector. Since some munici- palities have additional local codes, it is always best to consult your local authority and the National Fuel Gas Code, ANSI Z223.1/NFPA 54 in the USA or the CSA- B149.1 installation code.

12���

1���

(32 mm)

(318 mm)

 

 

 

 

 

 

 

 

6”

 

 

Gas Line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Line

(152 mm)

 

Opening in

Through Wall

 

 

 

 

 

 

Wall

 

 

 

 

 

 

FP1787

 

 

 

 

 

 

 

 

 

 

Fig. 7 Recommended gas line installation.

Always check for gas leaks with a mild soap and water solution applied with a brush no larger than 1” (25 mm). Never apply soap and water solution with a spray bottle. Do not use an open flame for leak testing.

The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi. Isolate or disconnect this or any other gas appliance control form the gas line when pressure testing.

The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to pro- vide a 1/8” test point up stream of the control.

When using a flex connector use only approved fittings. Always provide a union when using black iron pipe

so the gas line can be easily disconnected for burner servicing. See gas specification for pressure details and ratings.

The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi. Isolate or disconnect this and any other gas appliance control from the gas line when pressure testing.

6

20012301

Image 6
Contents Direct Vent Model DVR28IN Table of Contents Installation & Operating Instructions Certified ToAnsi Z21.88-2005 / CSA Vented Gas Fireplace Heaters DVR28 Fireplace Dimensions Fireplace specifications and framing dimensionsMounting the Fireplace Installation Instructions PreparationLocating Your Fireplace Clearance to CombustiblesGas Inlet and Manifold Pressures Gas Line InstallationGas Specifications High ElevationsRestrictor Plate Installation InstallationGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationGeneral Information Assembling Vent Pipes Canadian InstallationsUSA Installations Twist Lock PipesExample a How to Use the Vent GraphRear Wall Venting Applications Example BRear Wall Installation Twist Lock Pipe Zero clearance sleeve is only required for combustible wallsVertical Sidewall Applications Total angular variation =Below Grade Installations Vertical Through-the-Roof ApplicationVertical Through-the-Roof Installation Place firestop spacers and secureMinimum termination to roof clearance Venting Components Operating Instructions Window Frame Assembly RemovalGlass Cleaning Glass InformationFlame & Temperature Adjustment Flame CharacteristicsInspecting the Venting System Lighting Instructions Lighting & Operating InstructionsFor Fireplaces equipped with AF4000 Gas Valve Turning Off the Gas to the ApplianceTroubleshooting AF4000 ValveTroubleshooting AF4000 Valve Igniter operationTroubleshooting AF4000 Valve Fireplace May Be HOT MaintenanceCleaning the Standing Pilot Control System Burner and Burner CompartmentDescription DVR28Screen Door Kit Optional AccessoriesCurve Face Kit Model # ColorLimited Lifetime Warranty Efficiency Ratings 67.6 64.3