Vermont Castings DVR28 Direct Vent Gas Fireplace
Sheet Metal
Screws (8)
Wall Mounting Bracket
Secured to Walll
DVR28
Sheet Metal |
|
Screws (4) | FP1785 |
Fig. 6 Secure fireplace to wall mounting bracket.
Gas Specifications
|
|
| Max. | Min. | Air |
|
|
| Input | Input | Shutter |
Model | Fuel | Gas Control | BTU/h | BTU/h | Setting |
|
|
|
|
| 1/8” |
DVR28IN | Nat. | Millivolt Hi/Lo | 18,500 | 16,500 | open |
|
|
|
|
| on sides |
Gas Inlet and Manifold Pressures
| Natural |
Inlet Minimum | 5.5” w.c. |
Inlet Maximum | 14.0” w.c. |
Manifold Pressure | 3.5” w.c. |
High Elevations
Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the cur- rent ANSI Z223.1/NFPA 54 and/or local codes hav- ing jurisdiction.
In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m).
Remote ON/OFF Hi/Lo
Wall Mounted Transmitter
The DVR28 is equipped with a wireless transmitter. No wires are required.
Gas Line Installation
When purging the gas lines, the front win- dow frame assembly must be removed.
The gas pipeline can be brought in under the bottom of the fireplace. The gas line connections will be covered by bottom trim. Refer to Figure 7 for gas line dimen- sions. Use 1/2” rigid pipe. When gas line is in place un- der the fireplace, install supplied 1/2” FPT to 3/8” flare brass fitting. Connect preinstalled flex line on fireplace to brass fitting with 3/8” flare fitting on supply line.
The gas line connection can be made with 3/8” rigid pipe or an approved flex connector. Since some munici- palities have additional local codes, it is always best to consult your local authority and the National Fuel Gas Code, ANSI Z223.1/NFPA 54 in the USA or the CSA- B149.1 installation code.
12���” | 1���” | |
(32 mm) | ||
(318 mm) | ||
|
|
|
|
|
|
|
| 6” |
|
| Gas Line |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||||
Gas Line | (152 mm) |
| Opening in | |||||||
Through Wall |
|
|
|
|
|
| Wall | |||
|
|
|
|
|
| FP1787 | ||||
|
|
|
|
|
|
|
|
|
|
Fig. 7 Recommended gas line installation.
Always check for gas leaks with a mild soap and water solution applied with a brush no larger than 1” (25 mm). Never apply soap and water solution with a spray bottle. Do not use an open flame for leak testing.
The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi. Isolate or disconnect this or any other gas appliance control form the gas line when pressure testing.
The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to pro- vide a 1/8” test point up stream of the control.
When using a flex connector use only approved fittings. Always provide a union when using black iron pipe
so the gas line can be easily disconnected for burner servicing. See gas specification for pressure details and ratings.
The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi. Isolate or disconnect this and any other gas appliance control from the gas line when pressure testing.
6 | 20012301 |