Zanussi ZGF 642 manual Fault Finding, Preliminary Electrical Systems Check, Earth Continuity Check

Page 15

Fault Finding

Preliminary Electrical Systems Check

PLUG (with cover removed)

SOCKET

 

(face view)

Brown Blue Green Yellow

Blue

BrownGreen Yellow

START

Isolate appliance and carry out:

A:Earth Continuity check.

Earth Wire

( )

Green/Yellow

Neutral Wire

FUSE

 

Blue

 

N

E()

L

NO

YES

Carry out:

 

Carry out:

 

Electricity supply

 

D: Resistance to

 

 

should now be

 

 

 

C: Polarity check.

 

 

 

 

 

 

 

Earth check.

 

satisfactory.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Has inlet fuse blown?

NO

YES

Inlet wiring faulty. Rectify any fault.

Isolate appliance and carry out:

B:Insulation check. Rectify any fault including replacing fuses as necessary.

A. EARTH CONTINUITY CHECK -

Appliance must be electrically disconnected - meter set on Ω (Ohms) x 1 scale and adjust zero if necessary.

a)Test leads from any appliance earth point

to earth pin on plug. Resistance should be less than 0.1 Ω (Ohm), check all earth

wires for continuity and all contacts clean and tight.

B. INSULATION CHECK - Appliance electrically disconnected, all switches ON.

a)meter set on Ω (Ohms) x 1 scale.

Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit.

b)meter set on Ω (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads less than (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component.

It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.

16

Image 15
Contents GAS HOB Model ZGF During Use Important Safety InformationChild Safety ServiceContents Hob Top InstallationWhen the HOB is First Installed Description of the HobDiameter OperationHOB Burners Burner Minimum MaximumBurners Maintenance and CleaningHobTop Pan SupportsSomething Not Working? Symptom SolutionCustomer Care Service and Spare PartsZanussi Guarantee Conditions Peace of Mind for 24 MonthsCUT OUT Dimensions Instructions for the InstallerEngineer technical data Overall DimensionsLocation Important safety requirementsCut Out Size InstallationDimensions are given in mm Gas ConnectionFitting the Hob into the worktop BuildingThis HOB Must be Earthed Electrical connectionsTaps Ignitor Switches Ignitor Unit Wiring DiagramFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Procedure Pressure TestingCommissioning Servicing To Adjust the GAS Rate