Zanussi ZGF 642 manual Instructions for the Installer, Engineer technical data, Overall Dimensions

Page 9

Instructions for the Installer

Engineer technical data

OVERALL DIMENSIONS

Width:

580 mm.

Depth:

510 mm.

Height:

72 mm.

Weight:

12 Kg.

CUT OUT DIMENSIONS

Width:

560 mm.

Depth:

480 mm.

Thickness:

30 mm.

Ignition HT Spark

SUPPLY CONNECTIONS

Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

Spark Generator

Ispra Control's BF 50046-06 , 220-240V 0.6 VA T 120

Spark Gap

Fixed

 

 

 

Rear Left Burner (semi rapid)

Rear Right Burner (semi rapid)

Heat Input

2.0 kW (6824 BTU/HR)

 

 

 

 

 

Heat Input

2.0 kW (6824 BTU/HR)

Front Left Burner (auxiliary)

 

 

 

 

 

 

Front Right Burner (rapid)

Heat Input

1.0 kW (3412 BTU/HR)

 

 

 

 

 

Heat Input

3.0 kW (10236 BTU/HR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFTYPE

GAS

 

 

CHARACTERISTICS

 

BURNER

 

 

RAPID

SEMI-RAPID

 

AUXILIARY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(large)

(medium)

 

(small)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POSITION

 

 

MAX

 

MIN

MAX

MIN

MAX

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURALGAS

20mbar

 

=VALUE37.78 MJ/m3

50.7-WsMJ/ m

 

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

POWER

kW

 

3.0

 

0.65

 

2.0

0.45

 

1.0

0.33

 

 

 

 

 

 

 

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATE

m3/h

 

0.286

 

0.062

 

0.190

0.043

 

0.095

0.031

 

 

 

 

 

 

 

NOZZLE REFERENCE

 

119

 

Adjust.

96

Adjust.

 

70

Adjust.

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GASLPG

mbar30/37-28

 

MJ/Kg49.92=VALUE

 

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER

kW

 

2.8

 

0.65

 

2.0

0.45

 

1.0

0.33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATE

g/h

 

202

 

47

 

144

32

 

72

24

 

 

 

 

 

 

 

NOZZLE REFERENCE

 

86

 

40

 

71

32

 

50

28

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

APPLIANCE CLASS : 3

Burner

 

 

Dia. Tap By-pass

 

Tap colour

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

APPLIANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

 

28

 

Blue/Blue

 

 

CATEGORY: II2H3+

Semi-rapid

 

32

 

Black/Black

 

APPLIANCE

 

 

Rapid

 

 

40

 

Brown/Brown

 

 

 

 

 

 

 

GAS SUPPLY: Natural gas G20 / 20mbar

 

 

 

 

 

 

 

 

 

 

 

 

 

Aeration adjustment none

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

Image 9
Contents GAS HOB Model ZGF Child Safety Important Safety InformationService During UseContents When the HOB is First Installed InstallationDescription of the Hob Hob TopHOB Burners OperationBurner Minimum Maximum DiameterHobTop Maintenance and CleaningPan Supports BurnersSomething Not Working? Symptom SolutionZanussi Guarantee Conditions Service and Spare PartsPeace of Mind for 24 Months Customer CareEngineer technical data Instructions for the InstallerOverall Dimensions CUT OUT DimensionsLocation Important safety requirementsDimensions are given in mm InstallationGas Connection Cut Out SizeFitting the Hob into the worktop BuildingThis HOB Must be Earthed Electrical connectionsTaps Ignitor Switches Ignitor Unit Wiring DiagramFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Procedure Pressure TestingCommissioning Servicing To Adjust the GAS Rate