Electrolux 318201775 LP/Propane Gas Conversion, Moving the Appliance for Servicing and Cleaning

Page 5

30" GAS RANGE INSTALLATION INSTRUCTIONS

Do not use a flame to check for leaks from gas connections. Checking for leaks with a flame may result in a fire or explosion.

All openings in the wall or floor where the range is to be installed must be sealed.

Tighten all connections if necessary to prevent gas leakage in the cooktop or supply line.

Disconnect this range and its individual shutoff valve from the gas supply piping system during any pressure testing of the system at test pressures greater than 1/2 psig (3.5 kPa or 14"(35,56 cm) water column).

Isolate the range from the gas supply piping system

by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa or 14"(35,56 cm) water column).

4.LP/Propane Gas Conversion

This appliance can be used with Natural gas or LP/Propane gas. It is shipped from the factory for use with natural gas.

If you wish to convert your range for use with LP/ Propane gas, use the supplied fixed orifices located in a bag containing the literature marked "FOR LP/PROPANE GAS CONVERSION." Follow the instructions packaged with the orifices.

The conversion must be performed by a qualified service technician in accordance with the manufacturer's instructions and all local codes and requirements. Failure to follow these instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for the conversion.

Failure to make the appropriate conversion can result in personal injury and property damage.

5.Moving the Appliance for Servicing and Cleaning

Turn off the range line fuse or circuit breakers at the main power source, and turn off the manual gas shut-off valve. Make sure the range is cold. Open the oven door. Lift the range at the front and slide it out of the cut-out opening without creating undue strain on the flexible gas conduit. Make sure not to pinch the flexible gas conduit at the back of the range when replacing the unit into the cut-out opening. Close the door and switch on the electrical power and gas to the range.

6.Range Placement

To eliminate the risk of burns or fire from

reaching over heated surface units, cabinet storage space located above the range should be avoided. If cabinet storage space is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinet.

Center

Line of

Range

Follow instructions for

the type of installation you have

Figure 6

If range will be installed with a cabinet on both sides, draw a center line on the floor between the cabinets (see figure 6). If back of range will not be flush with the wall (the location of the outlet may not allow the range to be positioned against the wall), draw a line on the floor where the back edge of the range will be. Now install anti-tip bracket (see "Anti-Tip Bracket Installation", page 9).

If range will be installed with a cabinet on one side only, move the range into final position. Draw a line on the floor along the side of the range that is not against the cabinet. If back of range will not be flush with the wall (the location of the outlet may not allow the range to be positioned against the wall), draw a line on the floor where the back edge of the range will be. Now install anti-tip bracket (see "Anti-Tip Bracket Installation", page 9).

If range will not be installed against a cabinet, move range into final position. Draw a line on the floor along both sides of the range. If back of range will not be flush with the wall (the location of the outlet may not allow the range to be positioned against the wall), draw a line on the floor where the back edge of the range will be. Now install anti-tip bracket (see "Anti-Tip Bracket Installation", page 9).

5

Image 5
Contents Do not pinch the power supply cord between the range Cooktop and the bottom of the cabinet when the bottomWood or metal cabinet is protected by not less than 0.64 cm flame retardant millboard covered withEvent of an electrical power outage, the surface Adjust surface burner flame size so it does notBefore self-cleaning the oven. Wipe up excess Burned climbing on the range to reach itemsModel and Serial Number Location Important Notes to the InstallerImportant Note to the Consumer Optional Items AvailableSuggested gas connection Gas Supply InstallationConnection to Pressure Regulator Range Placement Moving the Appliance for Servicing and CleaningType of installation you have LP/Propane Gas ConversionExcessive Weight Hazard Check Operation Range InstallationLeveling the Range Burner Bases and Burner CapsGAS Range Installation Instructions Before You Call for Service When All Hookups are CompleteOperation of Oven Burners and Oven Adjustments Oven Burner Flame AdjustmentAnti-Tip Bracket Installation Important Safety WarningTools Required Range 11 5/16 28.7 cm 2 6.4 cmGAS Range Installation Instructions Instrucciones DE Instalacion Para LA Estufa DE GAS Importantes Instrucciones DE Seguridad Notas importantes para el Instalador Requisitos eléctricosNota Importante para el Consumidor Artículos Disponibles OpcionalesConexión del regulador Instalación de la alimentación de gasLas conexiones sugeridas en 30 modelo Regulador de presión incluidoLa mudanza del aparato para reparaciones o limpieza Conversión para uso de Propano LíquidoEstufa Colocación Apriete todas las conexiones si hace falta paraComprobación del Funcionamiento Instalación de la estufaPeligro de Peso Excesivo Nivelación de la estufaInstrucciones DE Instalacion Para LA Estufa DE GAS Operación de Quemadores del Horno y Ajustes de Horno Después de Terminar la InstalaciónAntes de Llamar al Servicio Instrucciones de Instalación del Soporte Antivuelco Importante Advertencia de SeguridadHerramientas Necesarias Base De la estufaWiring Diagram Diagrama DE LA Instalación Alámbrica