DeLonghi DEGESC24SS Electrical Requirements, Electrical Connection with Power Cord

Page 16

electrical connection

WARNING

TO AVOID ELECTRICAL SHOCK HAZARD, BEFORE INSTALLING THE APPLIANCE, SWITCH POWER OFF AT THE SERVICE PANEL AND LOCK THE PANEL TO PREVENT THE POWER F R O M B E I N G S W I T C H E D O N ACCIDENTALLY.

ELECTRICAL REQUIREMENTS

This appliance must be properly installed and grounded by a qualified technician in accordance with the National Electrical Code ANSI/NFPA No.70 (latest edition) and local electrical code requirements. IN CANADA: Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part1 and/or local codes.

This appliance may be connected by means of permanent “Hard Wiring” or “Power Supply Cord Kit”. Power supply cord is not supplied, but it is available through your local electric supply house.

Use only 3-conductor or 4-conductor CSA/UL listed range cord rated at 25 amps with 250 V minimum and provided with ring terminals. These cords should be pro- vided with strain relief or conduit connector.

Warning: Frame grounded through neutral lead. If used in,

-New branch-circuit installations (1996 NEC),

-Mobile homes,

-Recreational vehicles, or

-In an area where local codes prohibit grounding through neutral, use a 4 conductor cord or conduit.

The range must be connected to the proper electrical voltage and frequency as spec- ified on the rating plate.

The range can be connected directly to the fused disconnect (or circuit breaker box) through flexible, armoured or non-metallic sheathed, copper cable (with grounding wire). Allow two to three feet of slack in the line so that it can be moved if servicing is ever necessary.

ELECTRICAL CONNECTION WITH POWER CORD

Use a 3-wire power supply cord kit rated for 25 amps - 125/250 volts with closed loop terminals and marked for use with ranges. Where local codes do not permit grounding through neutral, use a 4-wire power supply cord kit.

The cord must be secured to the range with the strain relief supplied or with a suitable strain relief. The electrical connection is made at the terminal block, which is located behind the terminal block access plate on the back of the range.

ELECTRICAL CONNECTION WITH CONDUIT

Use 1/2” (1.3 cm) trade size CSA/UL-listed conduit with a conduit clamp, 16 AWG/600 volt copper conductor colored red for line 1 and black for line 2 and 16 AWG/600 volt copper conductor (or 12 AWG/600 Volt copper conductor if grounding through neutral) colored white for neutral with closed loop terminals marked for use with ranges.

Where local codes do not permit grounding through neutral, use a green 12 AWG cop- per conductor as directed in the 4-wire connector directions. The conduit must be secured to the range with the strain relief bracket. The electrical connection is made at the terminal block which is located behind the terminal block access plate on the back of the range.

16

Image 16
Contents GAS/ELECTRIC Range ALL Ranges can TIP Data Plate Conversion Label Installation Instructions Replacement Parts Electrical Grounding InstructionsElectrical Requirement Air Supply and VentilationProximity to Side Cabinets GAS and Electric ConnectionIt is mandatory to install the backguard Assembling the BackguardANTI-TIP Stability Device Installation Instructions Levelling the RangeExplosion Hazard Manual Shut-off Valve figPressure Regulator Pressure Regulator Installation Step Extension GAS Connection SpecificationPressure regulator Flexible Connections Leak TestingRigid Pipe Connections Conversion to LP/PROPANE GAS Setting the Pressure Regulator figTo remove the warming drawer To set the pressure regulator fig Fitting the warming drawer figSetting the Burner Minimum Operations to be Performed When Substituting the InjectorsInjectors Table Electrical Requirements Electrical Connection with Power CordElectrical Connection with Conduit Wire Power Cord Installation using Strain Relief Supplied Wire Power Cord Installation Wire Conduit Installation Wiring Diagram Energy RegulatorPage Page Page Cod ß4