DeLonghi DEGESC24SS installation instructions Wire Conduit Installation

Page 19

3-Wire Conduit Installation

(See Figures 3.1, 3.4, 3.8 and 3.9)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (fig. 3.1).

2.Remove the Bracket and Strain Relief group by unscrewing the Bracket Fixing Screws.

3.Mount the Conduit Bracket (supplied with the range in a sep- arate kit) inside the Opening For Electrical Connection by screwing the 2 Fixing Screws (as indicated in Figure 3.8).

4.Feed 1/2” (1.3 cm) trade size Conduit through the hole in the Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp.

5.Remove the 3 wire terminal nuts and washers from the Terminal Block.

6.Plug the terminal holes of conductors. The Neutral or Ground Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block. The Power Wires must be connected to the outside terminals.

7.Plug washers and tighten nuts securely.

Do not remove Ground strap.

8.Assemble the Terminal Block Access Plate.

4-Wire Conduit Installation

(See Figures 3.1, 3.4, 3.8 and 3.10)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (fig. 3.1).

2.Remove the Bracket and Strain Relief group by unscrewing the Bracket Fixing Screws.

3.Mount the Conduit Bracket (supplied with the range in a sep- arate kit) inside the Opening For Electrical Connection by screwing the 2 Fixing Screws (as indicated in Figure 3.8).

4.Feed 1/2” (1.3 cm) trade size Conduit through the hole in the Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp.

5.Remove the 3 wire terminal nuts and washers from the Terminal Block.

6.Remove the Ground Strap from the frame of range and ter- minal by removing its screw and cutting it as shown in Figure 3.10.

7.Plug the terminal holes of conductors. The Neutral Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block; the Power Wires

must be connected to the outside terminals; the Ground Wire must be attached to the frame of range by using the (Ground) identified Grounding Screw.

8.Plug washers and tighten nuts securely.

9.Assemble the Terminal Block Access Plate.

 

Fig. 3.8

Opening For

 

Electrical

 

Connection

 

 

Conduit Bracket

 

Fixing Screws

Counduit

Hole D 7/8"

Bracket

(22.5 mm)

Fig. 3.9

Terminal Block

Ground strap

Neutral Wire

Conduit Clamp

Power Wires

Conduit

 

Fig. 3.10

Terminal Block

Cut Ground Strap

 

Grounding Wire

Neutral Wire

 

Power Wires

Grounding Screw

Conduit

Conduit Clamp

 

19

Image 19
Contents GAS/ELECTRIC Range ALL Ranges can TIP Data Plate Conversion Label Installation Instructions Air Supply and Ventilation Replacement PartsElectrical Grounding Instructions Electrical RequirementGAS and Electric Connection Proximity to Side CabinetsAssembling the Backguard It is mandatory to install the backguardLevelling the Range ANTI-TIP Stability Device Installation InstructionsExplosion Hazard Manual Shut-off Valve figPressure Regulator Pressure Regulator Installation Step Extension GAS Connection SpecificationPressure regulator Flexible Connections Leak TestingRigid Pipe Connections Conversion to LP/PROPANE GAS Setting the Pressure Regulator figTo remove the warming drawer Fitting the warming drawer fig To set the pressure regulator figSetting the Burner Minimum Operations to be Performed When Substituting the InjectorsInjectors Table Electrical Requirements Electrical Connection with Power CordElectrical Connection with Conduit Wire Power Cord Installation using Strain Relief Supplied Wire Power Cord Installation Wire Conduit Installation Energy Regulator Wiring DiagramPage Page Page Cod ß4