DeLonghi DEGESC24SS Conversion to LP/PROPANE GAS, Setting the Pressure Regulator fig

Page 13

CONVERSION TO LP/PROPANE GAS

Every range is provided with a set of injectors for the various types of gas.

Select the injectors to be replaced according to the “INJECTORS TABLE”.

The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector.

SETTING THE PRESSURE REGULATOR (fig. 2.6)

The pressure regulator is accessible by removing the warmer drawer; the pressure regulator is positioned on the rear right side of the range (fig. 2.9).

To remove the warming drawer:

1.Open the drawer completely (fig. 2.6)

2.Move down the lever of left guide (fig. 2.7) and up the lever of right guide (fig. 2.8).

3.Remove the drawer; the levers have to be keep moved (fig. 2.6).

Fig. 2.8

2

3

2

Fig. 2.6

Fig. 2.7

13

Image 13
Contents GAS/ELECTRIC Range ALL Ranges can TIP Data Plate Conversion Label Installation Instructions Electrical Grounding Instructions Replacement PartsElectrical Requirement Air Supply and VentilationGAS and Electric Connection Proximity to Side CabinetsAssembling the Backguard It is mandatory to install the backguardLevelling the Range ANTI-TIP Stability Device Installation InstructionsExplosion Hazard Manual Shut-off Valve figPressure Regulator Pressure Regulator Installation Step Extension GAS Connection SpecificationPressure regulator Flexible Connections Leak TestingRigid Pipe Connections Conversion to LP/PROPANE GAS Setting the Pressure Regulator figTo remove the warming drawer Fitting the warming drawer fig To set the pressure regulator figSetting the Burner Minimum Operations to be Performed When Substituting the InjectorsInjectors Table Electrical Requirements Electrical Connection with Power CordElectrical Connection with Conduit Wire Power Cord Installation using Strain Relief Supplied Wire Power Cord Installation Wire Conduit Installation Energy Regulator Wiring DiagramPage Page Page Cod ß4