Verona VEFSGE 304 SC ANTI-TIP Stability Device Installation Instructions, Levelling the Range

Page 10

1

LEVELLING THE RANGE

The range is equipped with 4 LEVELLING FEET and may be levelled by screwing or unscrewing the feet (figs. 1.6 - 1.7).

It is important to observe the directions of figures 1.6, 1.8a, 1.8b.

Fig. 1.6

Supplied with the range

 

Supplied with the range

in a separate kit

 

in a separate kit

 

 

 

 

 

 

 

 

0”

 

+ 5/16”

 

 

 

0 mm

 

 

 

 

 

+ 8 mm

 

 

 

 

 

 

 

 

+ 5/16”

 

+ 11/16”

 

 

 

+ 8 mm

Fig. 1.8a

Fig. 1.8b

 

 

+ 17.5 mm

 

 

 

 

 

Fig. 1.7

 

 

 

 

YOU MUST USE STABILITY

ANTI-TIP STABILITY DEVICE INSTALLATION INSTRUCTIONS

ANTI TIP

BRACKET TO

1. The anti-tip bracket has to be attached as shown on figure below (only rear left side),

PREVENT

UNIT FROM

it has to be fixed on the floor OR on the rear wall by no. 4 (four) suitable screws (not

TIPPING.

 

supplied). Alternatively the anti-tip bracket can also be fixed on the floor AND on the

 

 

rear wall by no. 8 (eight) suitable screws (not supplied).

 

2.After fixing the anti-tip bracket, slide range into place. Be sure the rear left foot slides under the anti-tip bracket attached.

Dotted line showing the position

ANTI-TIP STABILITY of the range when installed

DEVICE FIXING

3” 15/64 (82 mm)

Anti-tip stability device

Rear left feet of range

10

Fig. 1.9

Image 10
Contents GAS/ELECTRIC Range What to do if YOU Smell GAS Data Plate Conversion Label Installation Instructions Replacement Parts Electrical Grounding InstructionsInstallation Proximity to Side CabinetsIt is mandatory to install the backguard Assembling the BackguardProximity to Side Cabinets Standard Installation Proximity to Side Cabinets Island Installation ANTI-TIP Stability Device Installation Instructions Levelling the RangeInstalling the Cooktop Front Guard Pressure Regulator Manual Shut-off Valve figExplosion Hazard Pressure Regulator Installation Step GAS Connection Speficication Flexible Connections Leak TestingRigid Pipe Connections Setting the Pressure Regulator To set the pressure regulator figOperations to be Performed When Substituting the Injectors Injectors TableSetting the Burner Minimum Semirapid burnerElectrical Requirements Electrical Connection with Power CordElectrical Connection with Conduit Wire Power Cord Installation See Figure =1 9/64 29 mm =7/8 22.5 mm Power CordWire Conduit Installation See Figure Plug the terminal holes of conductorsWiring Diagram Electric Diagram KEY