WARNING

TO AVOID ELECTRICAL SHOCK HA- ZARD, BEFORE INSTALLING THE APPLIANCE, SWITCH POWER OFF AT THE SERVICE PANEL AND LOCK THE PANEL TO PREVENT THE PO- WER FROM BEING SWITCHED ON ACCIDENTALLY.

electrical connection

3

 

 

 

ELECTRICAL REQUIREMENTS

This appliance must be properly installed and grounded by a qualified technician in accordance with the National Electrical Code ANSI/NFPA No.70 (latest edition) and local electrical code requirements.

This appliance may be connected by means of permanent “Hard Wiring” or “Power Supply Cord kit”.

Power supply cord is not supplied, but it is available through your local electric sup- ply house.

Use only 3-conductor or 4-conductor CSA/UL listed range cord rated at 30 amps with 250V minimum and provided with ring terminals. These cords should be provided with strain relief or conduit connector.

Warning: Frame grounded through neutral lead. If used in,

–– New branch-circuit installations (1996 NEC),

–– Mobile homes,

–– Recreational vehicles, or

–– In an area where local codes prohibit grounding through neutral, use a 4 con- ductor cord or conduit.

The range must be connected to the proper electrical voltage and frequency as specified on the rating plate.

The range can be connected directly to the fused disconnect (or circuit breaker box) through flexible, counduit with copper or aluminium wiring (with grounding wire).

Allow two to three feet of slack in the line so that it can be moved if servicing is ever necessary.

ELECTRICAL CONNECTION WITH POWER CORD

Use a 3-wire power supply cord kit rated for 30 amps - 240-208/120 volts with closed loop terminals and marked for use with ranges.

Where local codes do not permit grounding through neutral, use a 4-wire power supply cord.

The CSA/UL listed cord must be secured to the range with a suitable strain relief bra- cket.

The electrical connection is made at the terminal block, which is located behind the ac- cess door on the back of the range.

ELECTRICAL CONNECTION WITH CONDUIT

Use 1/2” (1.3 cm) trade size CSA/UL listed conduit with a conduit clamp, 16 AWG/600 volt copper conductor colored red for line 1 and black for line 2 and 16 AWG/600 volt copper conductor (or 14 AWG/600 volt copper conductor if grounding through neutral) colored white for neutral with closed loop terminals marked for use with ranges.

Where local codes do not permit grounding through neutral, use a green 14 AWG copper conductor as directed in the 4-wire connector directions.

The conduit must be secured to the range with the strain relief bracket.

The electrical connection is made at the terminal block, which is located behind the ac- cess door on the back of the range.

19

Image 19
Contents GAS/ELECTRIC Range What to do if YOU Smell GAS Data Plate Conversion Label Installation Instructions Electrical Grounding Instructions Replacement PartsProximity to Side Cabinets InstallationAssembling the Backguard It is mandatory to install the backguardProximity to Side Cabinets Standard Installation Proximity to Side Cabinets Island Installation Levelling the Range ANTI-TIP Stability Device Installation InstructionsInstalling the Cooktop Front Guard Pressure Regulator Manual Shut-off Valve figExplosion Hazard Pressure Regulator Installation Step GAS Connection Speficication Flexible Connections Leak TestingRigid Pipe Connections To set the pressure regulator fig Setting the Pressure RegulatorInjectors Table Operations to be Performed When Substituting the InjectorsSemirapid burner Setting the Burner MinimumElectrical Requirements Electrical Connection with Power CordElectrical Connection with Conduit =1 9/64 29 mm =7/8 22.5 mm Power Cord Wire Power Cord Installation See FigurePlug the terminal holes of conductors Wire Conduit Installation See FigureElectric Diagram KEY Wiring Diagram