Verona VEFSGE 304 SC manual Wire Power Cord Installation See Figure

Page 20

3

Fig. 3.1

Screws

Screws

Terminal Block

Access Plate

Fig. 3.2

 

 

 

Ground strap

 

 

Neutral Wire

Terminal Block

 

 

B

Power Cord

 

Bracket

 

 

 

 

A

 

A: D=1” 9/64 (29 mm)

 

B: D=7/8” (22.5 mm)

 

 

Power Cord

Power Wires

Fig. 3.3

 

 

 

Cut Ground Strap

 

 

Neutral Wire

Terminal Block

B

Power Cord

 

Bracket

Grounding

 

 

 

 

 

Screw

 

A

 

A: D=1” 9/64 (29 mm)

 

B: D=7/8” (22.5 mm)

 

 

Power Wires

Grounding Wire

 

Power Cord

20

 

 

 

3-Wire Power Cord Installation (See Figure 3.2)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (Figure 3.1).

2.Check the correct positioning of the Power Cord Bracket as per figure 3.2.

3.Assemble the strain relief in the hole on Power Cord Bracket.

4.Insert the Power Cord through the strain relief and tighten.

5.Remove the 3 wire terminal nuts and washers from the Termi- nal Block.

6.Plug the terminal holes of Power Cord.

The Neutral or Ground Wire of the Power Cord must be con- nected to the neutral terminal located in the center of Terminal Block.

The Power Wires must be connected to the outside terminals.

7.Plug washers and tighten nuts securely.

 Do not remove Ground strap.

8.Reassemble the Terminal Block Access Plate on the back of the range by screwing the 4 fixing Screws (Figure 3.1).

4-Wire Power Cord Installation (See Figure 3.3)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (Figure 3.1).

2.Check the correct positioning of the Power Cord Bracket as per figure 3.3.

3.Assemble the strain relief in the hole on Power Cord Bracket.

4.Insert the Power Cord through the strain relief and tighten.

5.Remove the 3 wire terminal nuts and washers from the Termi- nal Block.

6.Remove the Ground Strap from the frame of range and termi- nal by removing its screw and cutting it as shown in Figure 3.3.

7.Plug the terminal holes of Power Cord.

The Neutral Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block; the Power Wires must be connected to the outside terminals; the Ground Wire must be attached to the frame of range by using

the (Ground) identified Grounding Screw.

8.Plug washers and tighten nuts securely.

9.Reassemble the Terminal Block Access Plate on the back of the range by screwing the 4 fixing Screws (Figure 3.1).

Image 20
Contents GAS/ELECTRIC Range What to do if YOU Smell GAS Data Plate Conversion Label Installation Instructions Replacement Parts Electrical Grounding InstructionsInstallation Proximity to Side CabinetsIt is mandatory to install the backguard Assembling the BackguardProximity to Side Cabinets Standard Installation Proximity to Side Cabinets Island Installation ANTI-TIP Stability Device Installation Instructions Levelling the RangeInstalling the Cooktop Front Guard Explosion Hazard Manual Shut-off Valve figPressure Regulator Pressure Regulator Installation Step GAS Connection Speficication Rigid Pipe Connections Leak TestingFlexible Connections Setting the Pressure Regulator To set the pressure regulator figOperations to be Performed When Substituting the Injectors Injectors TableSetting the Burner Minimum Semirapid burnerElectrical Connection with Conduit Electrical Connection with Power CordElectrical Requirements Wire Power Cord Installation See Figure =1 9/64 29 mm =7/8 22.5 mm Power CordWire Conduit Installation See Figure Plug the terminal holes of conductorsWiring Diagram Electric Diagram KEY